Design and nondestructive imaging of a bioengineered vascular graft endothelium

dc.contributor.authorWhited, Bryce Matthewen
dc.contributor.committeechairRylander, M. Nicholeen
dc.contributor.committeememberXu, Yongen
dc.contributor.committeememberWang, Geen
dc.contributor.committeememberRylander, Christopher G.en
dc.contributor.committeememberSoker, Shayen
dc.contributor.committeememberGoldstein, Aaron S.en
dc.contributor.departmentBiomedical Engineeringen
dc.date.accessioned2013-02-19T22:43:54Zen
dc.date.available2013-02-19T22:43:54Zen
dc.date.issued2013-02-01en
dc.description.abstractCardiovascular disease is currently the leading cause of death in the U.S. that frequently requires bypass surgery using vascular grafts for treatment. Current limitations with fully synthetic grafts have led researchers to bioengineered alternatives that consist of a combination of vascular scaffolds and cells. A major challenge in creating a functional bioengineered vascular graft is development of a confluent endothelium on the lumen that is able to resist detachment under physiologic fluid flow. In addition, methodologies used to assess the growth and maturation of the endothelium in a noninvasive and dynamic manner are severely lacking. Therefore, the overall goal of this research is to advance the field of vascular tissue engineering by 1) creating methodologies to enhance EC adherence to a vascular graft and 2) development of a noninvasive and real-time imaging system capable of assessing the graft endothelium.  To achieve these objectives, three separate studies were performed. In the first study, electrospun scaffold fiber diameter and alignment were systematically varied to determine their effect on endothelial cell (EC) morphology and adherence under fluid flow. ECs on uniaxially aligned nanofibers displayed elongated and aligned morphologies leading to higher adherence to the scaffolds under physiologic levels of fluid flow as compared to those on randomly oriented scaffolds. In the second study, a fiber optic based (FOB) imaging system was developed to image fluorescent ECs through a thick electrospun scaffold.  Results demonstrated that the FOB imaging system was able to accurately visualize fluorescent ECs in a noninvasive manner through the thick and highly opaque scaffold. In the final study, the FOB imaging system was used to noninvasively quantify vascular graft endothelialization, EC detachment, and apoptosis through the vessel wall with greater imaging penetration depth than two-photon microscopy. Additionally, the FOB method was capable of continuously tracking EC migration and endothelialization of a bioengineered graft in a bioreactor. Overall, these results demonstrate that aligned scaffold topographies enhance EC adherence under fluid flow and the FOB imaging system is a promising tool to monitor endothelium development and response to fluid flow in a manner that has not previously been afforded using conventional imaging methods.en
dc.description.degreePh. D.en
dc.format.mediumETDen
dc.identifier.othervt_gsexam:140en
dc.identifier.urihttp://hdl.handle.net/10919/19260en
dc.publisherVirginia Techen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectTissue engineeringen
dc.subjectvascular graften
dc.subjectnondestructive imagingen
dc.subjectelectrospinningen
dc.subjectendothelial cellsen
dc.titleDesign and nondestructive imaging of a bioengineered vascular graft endotheliumen
dc.typeDissertationen
thesis.degree.disciplineBiomedical Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.leveldoctoralen
thesis.degree.namePh. D.en

Files

Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Whited_BM_D_2013.pdf
Size:
39.83 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
Whited_BM_D_2013_support_1.pdf
Size:
81.76 KB
Format:
Adobe Portable Document Format
Description:
Supporting documents