Long-term In-service Evaluation of Two Bridges Designed with Fiber-Reinforced Polymer Girders

dc.contributor.authorKassner, Bernard Leonarden
dc.contributor.committeechairCousins, Thomas E.en
dc.contributor.committeememberRoberts-Wollmann, Carin L.en
dc.contributor.committeememberLesko, John J.en
dc.contributor.departmentCivil Engineeringen
dc.date.accessioned2011-08-06T16:06:25Zen
dc.date.adate2004-09-23en
dc.date.available2011-08-06T16:06:25Zen
dc.date.issued2004-08-23en
dc.date.rdate2004-09-23en
dc.date.sdate2004-09-06en
dc.description.abstractA group of researchers, engineers, and government transportation officials have teamed up to design two bridges with simply-supported FRP composite structural beams. The Toms Creek Bridge, located in Blacksburg, Virginia, has been in service for six years. Meanwhile, the Route 601 Bridge, located in Sugar Grove, Virginia, has been in service for two years. Researchers have conducted load tests at both bridges to determine if their performance has changed during their respective service lives. The key design parameters under consideration are: deflection, wheel load distribution, and dynamic load allowance. The results from the latest tests in 2003 yield little, yet statistically significant, changes in these key factors for both bridges. Most differences appear to be largely temperature related, although the reason behind this effect is unclear. For the Toms Creek Bridge, the largest average values from the 2003 tests are 440 me for service strain, 0.43 in. (L/484) for service deflection, 0.08 (S/11.1) for wheel load distribution, and 0.64 for dynamic load allowance. The values for the Route 601 Bridge are 220 me, 0.38 in. (L/1230), 0.34 (S/10.2), and 0.14 for the same corresponding paramters. The recommended design values for the dynamic load allowance in both bridges have been revised upwards to 1.35 and 0.50 for the Toms Creek Bridge and Route 601 Bridge, respectively, to account for variability in the data. With these increased factors, the largest strain in the toms Creek Bridge and Route 601 Bridge would be less than 13% and 12%, respectively, of ultimate strain. Therefore, the two bridges continue to provide a large factor of safety against failure.en
dc.description.degreeMaster of Scienceen
dc.format.mediumETDen
dc.identifier.otheretd-09062004-152133en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-09062004-152133en
dc.identifier.urihttp://hdl.handle.net/10919/10122en
dc.publisherVirginia Techen
dc.relation.haspartKassner_Thesis.pdfen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectfiber-reinforced polymer (FRP)en
dc.subjectpultruded composite girdersen
dc.subjectdurabilityen
dc.subjectwheel load distributionen
dc.subjectdynamic load allowanceen
dc.subjectdeflectionen
dc.titleLong-term In-service Evaluation of Two Bridges Designed with Fiber-Reinforced Polymer Girdersen
dc.typeThesisen
thesis.degree.disciplineCivil Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Kassner_Thesis.pdf
Size:
2.88 MB
Format:
Adobe Portable Document Format

Collections