Department of Biomedical Engineering and Mechanics
Permanent URI for this community
A collaboration between School of Biomedical Engineering and Sciences and the Department of Engineering Science and Mechanics to form the Department of Biomedical Engineering and Mechanics.
Browse
Browsing Department of Biomedical Engineering and Mechanics by Department "Biological Systems Engineering"
Now showing 1 - 4 of 4
Results Per Page
Sort Options
- Exploring Host-Microbiome Interactions using an in Silico Model of Biomimetic Robots and Engineered Living CellsHeyde, Keith C.; Ruder, Warren C. (Springer Nature, 2015-07-16)The microbiome's underlying dynamics play an important role in regulating the behavior and health of its host. In order to explore the details of these interactions, we created an in silico model of a living microbiome, engineered with synthetic biology, that interfaces with a biomimetic, robotic host. By analytically modeling and computationally simulating engineered gene networks in these commensal communities, we reproduced complex behaviors in the host. We observed that robot movements depended upon programmed biochemical network dynamics within the microbiome. These results illustrate the model's potential utility as a tool for exploring inter-kingdom ecological relationships. These systems could impact fields ranging from synthetic biology and ecology to biophysics and medicine.
- Raman chemometric urinalysis (Rametrix) as a screen for bladder cancerHuttanus, Herbert M.; Vu, Tommy; Guruli, Georgi; Tracey, Andrew; Carswell, William; Said, Neveen; Du, Pang; Parkinson, Bing G.; Orlando, Giuseppe; Robertson, John L.; Senger, Ryan S. (2020-08-21)Bladder cancer (BCA) is relatively common and potentially recurrent/progressive disease. It is also costly to detect, treat, and control. Definitive diagnosis is made by examination of urine sediment, imaging, direct visualization (cystoscopy), and invasive biopsy of suspect bladder lesions. There are currently no widely-used BCA-specific biomarker urine screening tests for early BCA or for following patients during/after therapy. Urine metabolomic screening for biomarkers is costly and generally unavailable for clinical use. In response, we developed Raman spectroscopy-based chemometric urinalysis (Rametrix (TM)) as a direct liquid urine screening method for detecting complex molecular signatures in urine associated with BCA and other genitourinary tract pathologies. In particular, the Rametrix(TM)screen used principal components (PCs) of urine Raman spectra to build discriminant analysis models that indicate the presence/absence of disease. The number of PCs included was varied, and all models were cross-validated by leave-one-out analysis. In Study 1 reported here, we tested the Rametrix (TM) screen using urine specimens from 56 consented patients from a urology clinic. This proof-of-concept study contained 17 urine specimens with active BCA (BCA-positive), 32 urine specimens from patients with other genitourinary tract pathologies, seven specimens from healthy patients, and the urinalysis control Surine(TM). Using a model built with 22 PCs, BCA was detected with 80.4% accuracy, 82.4% sensitivity, 79.5% specificity, 63.6% positive predictive value (PPV), and 91.2% negative predictive value (NPV). Based on the number of PCs included, we found the Rametrix(TM)screen could be fine-tuned for either high sensitivity or specificity. In other studies reported here, Rametrix(TM)was also able to differentiate between urine specimens from patients with BCA and other genitourinary pathologies and those obtained from patients with end-stage kidney disease (ESKD). While larger studies are needed to improve Rametrix(TM)models and demonstrate clinical relevance, this study demonstrates the ability of the Rametrix(TM)screen to differentiate urine of BCA-positive patients. Molecular signature variances in the urine metabolome of BCA patients included changes in: phosphatidylinositol, nucleic acids, protein (particularly collagen), aromatic amino acids, and carotenoids.
- The Rametrix (TM) PRO Toolbox v1.0 for MATLAB (R)Senger, Ryan S.; Robertson, John L. (2020-01-06)Background. Existing tools for chemometric analysis of vibrational spectroscopy data have enabled characterization of materials and biologicals by their broad molecular composition. The Rametrix (TM) LITE Toolbox v1.0 for MATLAB (R) is one such tool available publicly. It applies discriminant analysis of principal components (DAPC) to spectral data to classify spectra into user-defined groups. However, additional functionality is needed to better evaluate the predictive capabilities of these models when "unknown" samples are introduced. Here, the Rametrix (TM) PRO Toolbox v1.0 is introduced to provide this capability. Methods. The Rametrix (TM) PRO Toolbox v1.0 was constructed for MATLAB (R) and works with the Rametrix (TM) LITE Toolbox v1.0. It performs leave-one-out analysis of chemometric DAPC models and reports predictive capabilities in terms of accuracy, sensitivity (true-positives), and specificity (true-negatives). Rametrix (TM) PRO is available publicly through GitHub under license agreement at: https://github.com/SengerLab/RametrixPROToolbox. Rametrix (TM) PRO was used to validate Rametrix (TM) LITE models used to detect chronic kidney disease (CKD) in spectra of urine obtained by Raman spectroscopy. The dataset included Raman spectra of urine from 20 healthy individuals and 31 patients undergoing peritoneal dialysis treatment for CKD. Results. The number of spectral principal components (PCs) used in building the DAPC model impacted the model accuracy, sensitivity, and specificity in leave-one-out analyses. For the dataset in this study, using 35 PCs in the DAPC model resulted in 100% accuracy, sensitivity, and specificity in classifying an unknown Raman spectrum of urine as belonging to a CKD patient or a healthy volunteer. Models built with fewer or greater number of PCs showed inferior performance, which demonstrated the value of Rametrix (TM) PRO in evaluating chemometric models constructed with Rametrix (TM) LITE.
- Spectral characteristics of urine specimens from healthy human volunteers analyzed using Raman chemometric urinalysis (Rametrix)Senger, Ryan S.; Kavuru, Varun; Sullivan, Meaghan; Gouldin, Austin; Lundgren, Stephanie; Merrifield, Kristen; Steen, Caitlin; Baker, Emily; Vu, Tommy; Agnor, Ben; Martinez, Gabrielle; Coogan, Hannah; Carswell, William; Karageorge, Lampros; Dev, Devasmita; Du, Pang; Sklar, Allan; Orlando, Giuseppe; Pirkle, James, Jr.; Robertson, John L. (PLOS, 2019-09-27)Raman chemometric urinalysis (Rametrix™) was used to analyze 235 urine specimens from healthy individuals. The purpose of this study was to establish the “range of normal” for Raman spectra of urine specimens from healthy individuals. Ultimately, spectra falling outside of this range will be correlated with kidney and urinary tract disease. Rametrix™ analysis includes direct comparisons of Raman spectra but also principal component analysis (PCA), discriminant analysis of principal components (DAPC) models, multivariate statistics, and it is available through GitHub as the Rametrix™ LITE Toolbox for MATLAB®. Results showed consistently overlapping Raman spectra of urine specimens with significantly larger variances in Raman shifts, found by PCA, corresponding to urea, creatinine, and glucose concentrations. A 2-way ANOVA test found that age of the urine specimen donor was statistically significant (p < 0.001) and donor sex (female or male identification) was less so (p = 0.0526). With DAPC models and blind leave-one-out build/test routines using the Rametrix™ PRO Toolbox (also available through GitHub), an accuracy of 71% (sensitivity = 72%; specificity = 70%) was obtained when predicting whether a urine specimen from a healthy unknown individual was from a female or male donor. Finally, from female and male donors (n = 4) who contributed first morning void urine specimens each day for 30 days, the co-occurrence of menstruation was found statistically insignificant to Rametrix™ results (p = 0.695). In addition, Rametrix™ PRO was able to link urine specimens with the individual donor with an average of 78% accuracy. Taken together, this study established the range of Raman spectra that could be expected when obtaining urine specimens from healthy individuals and analyzed by Rametrix™ and provides the methodology for linking results with donor characteristics.