VTechWorks staff will be away for the Thanksgiving holiday beginning at noon on Wednesday, November 22, through Friday, November 24, and will not be replying to requests during this time. Thank you for your patience, and happy holidays!

Show simple item record

dc.contributor.authorSandu, Simonel Ioanen_US
dc.date.accessioned2001-01-09en_US
dc.date.accessioned2014-03-14T20:30:06Z
dc.date.available2002-01-09en_US
dc.date.available2014-03-14T20:30:06Z
dc.date.issued2000-12-13en_US
dc.date.submitted2001-01-04en_US
dc.identifier.otheretd-01042001-122834en_US
dc.identifier.urihttp://hdl.handle.net/10919/30798
dc.description.abstractNitrification performance of three, fluidized-bed filters was investigated. Each filter contained 10 L of plastic bead medium (near neutral specific gravity and 2-4 mm diameter and length) and was loaded under conditions of various flow rates and ammonia levels. Bead settled depth and biofilter diameter (12.7, 15.2 and 17.8 cm) were the factors differing among the filters. The experiments were conducted with three replicate recirculating systems. Each system included one of the three different biofilter types, connected in parallel to a reservoir containing 500 L of water. Systems were allowed to acclimate using a synthetic nutrient substrate, which was followed by a comparative analysis of biofilter performance. To evaluate filter performance, ammonia inflow concentration, ammonia loading rates, nitrite, nitrate, temperature, pH, dissolved oxygen levels, hardness, alkalinity and flow rates were monitored. Initially, four different flow rates, ranging from 6 Lpmâ 12 Lpm, were tested at constant ammonia feed level (8.4 g/day). Here, biofilter D3 (17.8 cm diameter) showed the best ammonia removal performance at a flow rate of 6 Lpm, followed by the performance of D1 (12.7 Lpm) and D2 (15.2 Lpm). The difference in ammonia and nitrite removal performance decreased among the biofilters, as flow rate increased. An increase in flow rate also lowered ammonia level in the systems at a constant ammonia loading, but did not affect the nitrite concentration. Five different ammonia feed rates, ranging from 8.4 â 16.8 g/day, were tested in the second part of the study, at a constant flow rate of 12 Lpm in each column. Different ammonia and nitrite removal performance was observed between biofilter sizes. Ammonia accumulated in the tanks as ammonia loading increased, but nitrite concentration remained relatively constant. The results indicated that nitrification performance improved by 17 % as the applied flow rate was increased. Ammonia concentration decreased slightly, from 0.6 mg/L to 0.5 mg/L. The performance appeared to be limited at higher ammonia loadings, at which time ammonia concentration increased from 0.5 to 0.99 mg/L. Data on biofilm development indicates a reduction in biofilm thickness as flow rate was increase, and significant biofilm accumulation as ammonia supply increased. The results of this work were compared to performance data generated using a steady state biofilm model, developed by Rittmann and McCarty (1980). The model predicted higher values of biofilm thickness (Lf) than those seen in this study. Fluidized bed filters with plastic bead medium proved to be effective in removing ammonia and nitrite from a synthetic aquaculture water.en_US
dc.publisherVirginia Techen_US
dc.relation.haspartABSTRACT.pdfen_US
dc.relation.haspartTHESIS.pdfen_US
dc.rightsI hereby certify that, if appropriate, I have obtained and attached hereto a written permission statement from the owner(s) of each third party copyrighted matter to be included in my thesis, dissertation, or project report, allowing distribution as specified below. I certify that the version I submitted is the same as that approved by my advisory committee. I hereby grant to Virginia Tech or its agents the non-exclusive license to archive and make accessible, under the conditions specified below, my thesis, dissertation, or project report in whole or in part in all forms of media, now or hereafter known. I retain all other ownership rights to the copyright of the thesis, dissertation or project report. I also retain the right to use in future works (such as articles or books) all or part of this thesis, dissertation, or project report.en_US
dc.subjectnitrificatrionen_US
dc.subjectfluidized-bed filteren_US
dc.subjectwater recirculationen_US
dc.titleFactors Influencing the Nitrification Efficiency of Fluidized Bed Filters With a Plastic Bead Mediumen_US
dc.typethesisen_US
dc.contributor.departmentFisheries and Wildlife Sciencesen_US
thesis.degree.nameMaster of Scienceen_US
thesis.degree.levelmastersen_US
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen_US
dc.contributor.committeechairBoardman, Gregory D.en_US
dc.contributor.committeememberFlick, George J. Jr.en_US
dc.contributor.committeememberWatten, Barnaby J.en_US
dc.contributor.committeememberBrazil, Brian L.en_US
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-01042001-122834/en_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record