Acousto-Ultrasonic Evaluation of Cyclic Fatigue of Spot Welded Structures

Files
final.pdf (623.07 KB)
Downloads: 182
TR Number
Date
1997-08-28
Journal Title
Journal ISSN
Volume Title
Publisher
Virginia Tech
Abstract

An acousto-ultrasonic approach is used to explore the damage development in tensile shear spot welds during fatigue loading. There is reasonable data to support the hypothesis that a decrease in an AU signal is indicative of the presence of an internal crack and could be used for monitoring and evaluation purposes.

Description
Keywords
NDE, Acousto-Ultrasonic, Fatigue, Spot Weld, Ultrasonic
Citation
Collections