dc.description.abstractThis thesis presents results of an experimental investigation to characterize single straight steel fiber pullout in Ultra-High Performance Concrete (UHPC). Several parameters were explored including the distance of fibers to the edge of specimen, distance between fibers, and fiber volume in the matrix. The pullout load versus slip curve was recorded, from which the pullout work and maximum pullout load for each series of parameters were obtained. The curves were fitted to an existing fiber pullout model considering bond-fracture energy, Gd, bond frictional stress, 𝛕0, and slip hardening-softening coefficient, 𝜷. The representative load-slip curve characterizing the fiber pullout behavior will be implemented into a computational modeling protocol, for concrete structures, based on Lattice Discrete Particle Modeling (LDPM). The parametric study showed that distances over 12.7 mm from the edge of the specimen have no significant effect on the maximum pullout load and work. Edge distances of 3.2 mm decreased the average pullout work by 26% and the maximum pullout load by 24% for mixes with 0% fiber volume. The distance between fibers did not have a significant effect on the pullout behavior within this study. Slight differences in pullout behavior between the 2% and 4% fiber volumes were observed including slight increase in the maximum pullout load when increasing fiber volume. The suggested fitted parameters for modeling with 2% and 4% fiber volumes are a bond-fracture energy value of zero, a bond friction coefficient of 2.6 N/mm² and 2.9 N/mm² and a slip-hardening coefficient of 0.21 and 0.18 respectively.en_US
dc.format.mediumETDen_US
dc.publisherVirginia Techen_US
dc.rightsThis Item is protected by copyright and/or related rights. Some uses of this Item may be deemed fair and permitted by law even without permission from the rights holder(s), or the rights holder(s) may have licensed the work for use under certain conditions. For other uses you need to obtain permission from the rights holder(s).en_US
dc.subjectfiber pullouten_US
dc.subjectproximity effecten_US
dc.subjectUltra-High Performance Concreteen_US
dc.subjectbond slipen_US
dc.titleSingle Straight Steel Fiber Pullout Characterization in Ultra-High Performance Concreteen_US
dc.typeThesisen_US
dc.contributor.departmentCivil and Environmental Engineeringen_US
dc.description.degreeMSen_US
thesis.degree.nameMSen_US
thesis.degree.levelmastersen_US
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen_US
thesis.degree.disciplineCivil Engineeringen_US
dc.contributor.committeechairMoen, Cristopher Dennisen_US
dc.contributor.committeememberRoberts-Wollmann, Carin Len_US
dc.contributor.committeememberKoutromanos, Ioannisen_US