VTechWorks staff will be away for the Thanksgiving holiday beginning at noon on Wednesday, November 22, through Friday, November 24, and will not be replying to requests during this time. Thank you for your patience, and happy holidays!

Show simple item record

dc.contributor.authorZora, Leydi Tatianaen_US
dc.date.accessioned2016-07-25T06:00:20Z
dc.date.available2016-07-25T06:00:20Z
dc.date.issued2015-01-31en_US
dc.identifier.othervt_gsexam:4409en_US
dc.identifier.urihttp://hdl.handle.net/10919/71829
dc.description.abstractSynchrophasor Measurement Units (PMUs) are devices that can not only measure but also time stamp voltage, current, frequency, among others. PMUs take these synchronized measurements as fast as 60 times per second; compared with the traditional 2-4 second SCADA measurements, PMUs bring a much clear and real-time picture of what is happening in the power system. PMUs have been increasingly deployed across transmission power grids worldwide. In the USA this is primarily done by utilities through projects sponsored mainly by SIGS and Smart Grid grants. There are different applications that synchrophasors can provide, including off-line and real-time applications. However, due to budget constraints, technology development and characteristics specific to each system, not all applications are equally suitable and essential for all electric power systems. This thesis provides a method for PMU applications prioritization based on the analysis and results of wide area disturbance events.en_US
dc.format.mediumETDen_US
dc.publisherVirginia Techen_US
dc.rightsThis Item is protected by copyright and/or related rights. Some uses of this Item may be deemed fair and permitted by law even without permission from the rights holder(s), or the rights holder(s) may have licensed the work for use under certain conditions. For other uses you need to obtain permission from the rights holder(s).en_US
dc.subjectSynchrophasoren_US
dc.subjectPhasor measurement uniten_US
dc.subjectprioritizationen_US
dc.subjectnon-quantifiable criteriaen_US
dc.titleThesis PMU Applications Prioritization Based in Wide Area Disturbance Eventsen_US
dc.typeThesisen_US
dc.contributor.departmentElectrical and Computer Engineeringen_US
dc.description.degreeMSen_US
thesis.degree.nameMSen_US
thesis.degree.levelmastersen_US
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen_US
thesis.degree.disciplineElectrical Engineeringen_US
dc.contributor.committeechairDe La Reelopez, Jaimeen_US
dc.contributor.committeememberCenteno, Virgilio Aen_US
dc.contributor.committeememberPhadke, Arun Gen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record