    An Electrometer Design and Characterization for a CubeSat Neutral Pressure Instrument

    Thumbnail
    View/Open
    Supporting documents (174.2Kb)
    Downloads: 52
    Rohrer_TE_T_2017.pdf (18.89Mb)
    Downloads: 2601
    Date
    2017-02-02
    Author
    Rohrer, Todd Edward Bloomquist
    Metadata
    Show full item record
    Abstract
    Neutral gas pressure measurements in low Earth orbit (LEO) can facilitate the monitoring of atmospheric gravity waves, which can trigger instabilities that severely disrupt radio frequency communication signals. The Space Neutral Pressure Instrument (SNeuPI) is a low-power instrument detecting neutral gas density in order to determine neutral gas pressure. SNeuPI consists of an ionization chamber and a logarithmic electrometer circuit. The Rev. 1 SNeuPI electrometer prototype does not function as designed. A Rev. 2 electrometer circuit must be designed and its performance characterized across specified operating temperature and input current ranges. This document presents a design topology for the Rev. 2 electrometer and a derivation of the theoretical circuit transfer function. Component selection and layout are discussed. A range of predicted operating input currents is calculated using modeled neutral density data for a range of local times, altitudes, and latitudes corresponding to the conditions expected for the Lower Atmosphere/Ionosphere Coupling Experiment (LAICE) CubeSat mission. Laboratory test setups for measurements performed both under vacuum and at atmospheric pressure are documented in detail. Test procedures are presented to characterize the performance of the Rev. 2 electrometer at a range of controlled operating temperatures. The results of these tests are then extrapolated in order to predict the operation of the circuit at specified temperatures outside of the range controllable under laboratory test conditions. The logarithmic conformance, accuracy, sensitivity, power consumption, and deviations from expected response of the circuit are characterized. The results validate the electrometer for use under its expected flight conditions.
    URI
    http://hdl.handle.net/10919/74916
    Collections
    • Masters Theses [19418]

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us
     

     

    VTechWorks

    AboutPoliciesHelp

    Browse

    All of VTechWorksCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Log inRegister

    Statistics

    View Usage Statistics

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us