Search
Now showing items 1-1 of 1
The effect of chromium plating on the endurance limit of 4340 steel
(Virginia Tech, 1952-06-05)
The percentage of reduction in fatigue limit of AISI 4340 steel due to one chromium plating was 21 percent, based on the fatigue limit of unplated AISI 4340 steel.