Browsing by Author "Keebaugh, Audrey Elizabeth"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- Evaluation of a Feline-Optimized TSH Assay in Cats With Hyperthyroidism and With Non-Thyroidal IllnessBrassard, Camille (Virginia Tech, 2024-08-13)About 10% of hyperthyroid cats have a normal total T4 (TT4), requiring further testing to make the diagnosis. Thyroid stimulating hormone (TSH) is measured using the "canine" assay (TSH-CLIA, Immulite 2000 by Siemens) as the only assay currently available. However, this assay cannot differentiate between subnormal and low-normal TSH concentrations in cats due to poor specificity (70-85%). A novel feline-optimized TSH assay (TSH-BAW, Truforma by Zomedica) was recently developed. It allows differentiation between euthyroid and hyperthyroid cats. However, the effect of non-thyroidal illness (NTI) on TSH-BAW has not been evaluated. Our objectives included the comparison of serum TSH concentration using both the TSH-CLIA and TSH-BAW assays among hyperthyroid cats, cats with NTI, and healthy cats, and the evaluation of the sensitivity and specificity of the TSH-BAW for diagnosis of FHT. This prospective cross-sectional study was performed on 102 client-owned cats, including 37 hyperthyroid, 33 healthy, and 32 NTI cats. The following thyroid hormones were measured in all cats: TT4, TSH with both assays (Immulite 2000 and Truforma). Hyperthyroidism was confirmed by thyroid scintigraphy. Euthyroidism was confirmed by repeating TT4 measurement at least three months after enrollment (if available) to rule out subclinical hyperthyroidism. Cats with NTI were further divided based on the severity of their illness. Serum TSH was compared among groups using Kruskal-Wallis followed by Dunn's procedure, and compared among NTI severity scores using the Fisher's Exact test. Significance was set at P <0.05. The sensitivity and specificity of TSH-BAW for detecting hyperthyroidism are 78% (62-90%) and 97% (84-100%), respectively. The median TSH is significantly different between hyperthyroid cats and healthy and NTI cats with both assays (P<0.01). The TSH was not different between the latter euthyroid groups (P=0.87 and P=0.29). Eight (21.6%) hyperthyroid cats have a normal TSH-BAW but undetectable TSH-CLIA. Twelve (4 healthy, 8 NTI) euthyroid cats (18.5%) have an undetectable TSH-CLIA with only two (1 healthy, 1 NTI) (3%) having an undetectable TSH-BAW. The proportion of cats with a suppressed TSH is higher with severe illnesses with the TSH-CLIA only. In conclusion, the TSH-BAW has a high specificity, identifies normal TSH in healthy cats more often, and appears to not be affected by NTI. It can be a useful tool for the diagnosis of feline hyperthyroidism. However, a low-normal TSH cannot be used to rule out hyperthyroidism.
- Evaluation of hemostasis in hyperthyroid catsKeebaugh, Audrey Elizabeth (Virginia Tech, 2020-07-17)Background: Hyperthyroid cats are predisposed to thrombus formation. The mechanism for thrombogenesis is currently unknown, but could be associated with altered hemostasis as seen in hyperthyroid humans. Objective: The purpose of this study was to evaluate markers of hemostasis in hyperthyroid cats compared to healthy cats, and in hyperthyroid cats before and after treatments with radioactive iodine (RIT). Methods: Twenty-five cats with hyperthyroidism and 13 healthy euthyroid cats > 8 years of age were studied. Prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, antithrombin (AT), D-dimers, thrombin-antithrombin complexes (TAT), von Willebrand Factor antigen (vWF:Ag), and activity of factors VIII and IX were measured. An echocardiogram was performed in all cats and healthy cats with abnormal echocardiograms were excluded. Measurements of hemostasis were evaluated again in 7 cats > 6 months after RIT and deemed to have restored euthyroid status. Results: There is a significant likelihood of being in hypercoagulable state based on hyperthyroid state (P = 0.019) and serum T4 level is significantly associated with predicating hypercoagulability (P = 0.043). Hyperthyroidism is associated with significantly higher median fibrinogen concentration (P < 0.0001), higher median AT activity (P < 0.0001), and higher median vWF:Ag level (P = 0.01) with all values decreasing significantly post-RIT. Fibrinogen and AT had a strong positive correlation with serum T4 value (r = 0.79; 95% CI 0.63 - 0.89 and r = 0.70; 95% CI 0.50 - 0.84, respectively). Presence of an abnormal echocardiogram in hyperthyroid cats was associated with a significantly higher median fibrinogen concentration (P = 0.03). Echocardiographic status did not have a significant impact on the remaining hemostatic markers in hyperthyroid cats. Conclusions: These results provide evidence of altered hemostasis and hypercoagulability in hyperthyroid cats that do not appear to be solely attributed to cardiac abnormalities. These differences of altered hemostasis resolved after radioiodine therapy, but further studies are warranted to determine if hypercoagulable state resolves.