Browsing by Author "Ruan, Hang"
Now showing 1 - 5 of 5
Results Per Page
Sort Options
- Development of a Flexible Integrated Self-Calibrating MEMS Pressure Sensor Using a Liquid-to-Vapor Phase ChangeKang, Yuhong; Mouring, Scott; de Clerck, Albrey; Mao, Shuo; Ng, Wing; Ruan, Hang (MDPI, 2022-12-12)Self-calibration capabilities for flexible pressure sensors are greatly needed for fluid dynamic analysis, structure health monitoring and wearable sensing applications to compensate, in situ and in real time, for sensor drifts, nonlinearity effects, and hysteresis. Currently, very few self-calibrating pressure sensors can be found in the literature, let alone in flexible formats. This paper presents a flexible self-calibrating pressure sensor fabricated from a silicon-on-insulator wafer and bonded on a polyimide substrate. The sensor chip is made of four piezoresistors arranged in a Wheatstone bridge configuration on a pressure-sensitive membrane, integrated with a gold thin film-based reference cavity heater, and two thermistors. With a liquid-to-vapor thermopneumatic actuation system, the sensor can create precise in-cavity pressure for self-calibration. Compared with the previous work related to the single-phase air-only counterpart, testing of this two-phase sensor demonstrated that adding the water liquid-to-vapor phase change can improve the effective range of self-calibration from 3 psi to 9.5 psi without increasing the power consumption of the cavity micro-heater. The calibration time can be further improved to a few seconds with a pulsed heating power.
- Dual-Use Strain Sensors for Acoustic Emission and Quasi-Static Bending MeasurementsStiefvater, Jason; Kang, Yuhong; de Clerck, Albrey; Mao, Shuo; Jones, Noah; Deem, Josh; Wicks, Alfred; Ruan, Hang; Ng, Wing (MDPI, 2024-03-02)In this paper, a MEMS piezoresistive ultrathin silicon membrane-based strain sensor is presented. The sensor’s ability to capture an acoustic emission signal is demonstrated using a Hsu–Nielsen source, and shows comparable frequency content to a commercial piezoceramic ultrasonic transducer. To the authors’ knowledge, this makes the developed sensor the first known piezoresistive strain sensor which is capable of recording low-energy acoustic emissions. The improvements to the nondestructive evaluation and structural health monitoring arise from the sensor’s low minimum detectable strain and wide-frequency bandwidth, which are generated from the improved fabrication process that permits crystalline semiconductor membranes and advanced polymers to be co-processed, thus enabling a dual-use application of both acoustic emission and static strain sensing. The sensor’s ability to document quasi-static bending is also demonstrated and compared with an ultrasonic transducer, which provides no significant response. This dual-use application is proposed to effectively combine the uses of both strain and ultrasonic transducer sensor types within one sensor, making it a novel and useful method for nondestructive evaluations. The potential benefits include an enhanced sensitivity, a reduced sensor size, a lower cost, and a reduced instrumentation complexity.
- The Effect of Density Ratio on Steep Injection Angle Purge Jet Cooling for a Converging Nozzle Guide Vane Endwall at Transonic ConditionsSibold, Ridge Alexander (Virginia Tech, 2019-09-17)The study presented herein describes and analyzes a detailed experimental investigation of the effects of density ratio on endwall thermal performance at varying blowing rates for a typical nozzle guide vane platform purge jet cooling scheme. An axisymmetric converging endwall with an upstream doublet staggered cylindrical hole purge jet cooling scheme was employed. Nominal exit flow conditions were engine representative and as follows: {rm Ma}_{Exit} = 0.85, {rm Re}_{Exit,C_{ax}} = 1.5 times {10}^6, and large-scale freestream Tu = 16%. Two blowing ratios were investigated corresponding to the upper and lower engine extrema. Each blowing ratio was investigated amid two density ratios; one representing typical experimental neglect of density ratio, at DR = 1.2, and another engine representative density ratio achieved by mixing foreign gases, DR = 1.95. All tests were conducted on a linear cascade in the Virginia Tech Transonic Blowdown Wind Tunnel using IR thermography and transient data reduction techniques. Oil paint flow visualization techniques were used to gather quantitative information regarding the alteration of endwall flow physics due two different blowing rates of high-density coolant. High resolution endwall adiabatic film cooling effectiveness, Nusselt number, and Net Heat Flux Reduction contour plots were used to analyze the thermal effects. The effect of density is dependent on the coolant blowing rate and varies greatly from the high to low blowing condition. At the low blowing condition better near-hole film cooling performance and heat transfer reduction is facilitated with increasing density. However, high density coolant at low blowing rates isn't adequately equipped to penetrate and suppress secondary flows, leaving the SS and PS largely exposed to high velocity and temperature mainstream gases. Conversely, it is observed that density ratio only marginally affects the high blowing condition, as the momentum effects become increasingly dominant. Overall it is concluded density ratio has a first order impact on the secondary flow alterations and subsequent heat transfer distributions that occur as a result of coolant injection and should be accounted for in purge jet cooling scheme design and analysis. Additionally, the effect of increasing high density coolant blowing rate was analyzed. Oil paint flow visualization indicated that significant secondary flow suppression occurs as a result of increasing the blowing rate of high-density coolant. Endwall adiabatic film cooling effectiveness, Nusselt number, and NHFR comparisons confirm this. Low blowing rate coolant has a more favorable thermal impact in the upstream region of the passage, especially near injection. The low momentum of the coolant is eventually dominated and entrained by secondary flows, providing less effectiveness near PS, near SS, and into the throat of the passage. The high momentum present for the high blowing rate, high-density coolant suppresses these secondary flows and provides enhanced cooling in the throat and in high secondary flow regions. However, the increased turbulence impartation due to lift off has an adverse effect on the heat load in the upstream region of the passage. It is concluded that only marginal gains near the throat of the passage are observed with an increase in high density coolant blowing rate, but severe thermal penalty is observed near the passage onset.
- Numerical Study of the Thermal Performance of a Mems Pressure Sensor with Self-Calibration Capabilitiesde Clerck, Albrey; Kang, Yuhong; Sibold, Ridge; Mouring, Scott; Ruan, Hang; Ng, Wing (MDPI, 2022-05-18)Recent industry trends toward more complex and interconnected systems have increased the demand for more reliable pressure sensors. By integrating a microactuator with a pressure sensor, the sensor can self-calibrate, eliminating the complexities and costs associated with traditional sensor calibration methods to ensure reliability. The present work is focused on furthering understanding and improving the thermal performance of a thermopneumatic actuated self-calibrating pressure sensor. A transient numerical model was developed in ANSYS and was calibrated using experimental testing data. The numerical model provided insights into the sensor’s performance not previously observed in experimental testing. Furthermore, the model was utilized for two design studies. First, it was found that a substrate with low thermal conductivity and high thermal diffusivity is ideal for both the sensor’s efficiency and a faster transient response time. The second design study showed that decreasing the size of the sealed reference cavity lowers power consumption and transient response time. The study also showed that reducing the cavity base dimension has a greater effect on lowering power consumption and response time. Overall, the present work increases understanding of the self-calibrating pressure sensor and provides insight into potential design improvements, moving closer to optimized self-calibrating pressure sensors.
- Observation of Quantized and Partial Quantized Conductance in Polymer- Suspended Graphene NanoplateletsKang, Yuhong; Ruan, Hang; Claus, Richard O.; Heremans, Jean J.; Orlowski, Marius K. (SpringerOpen, 2016)Quantized conductance is observed at zero magnetic field and room temperature in metal-insulator-metal structures with graphene submicron-sized nanoplatelets embedded in a 3-hexylthiophene (P3HT) polymer layer. In devices with medium concentration of graphene platelets, integer multiples of Go = 2e2/h (=12.91 kΩ−1), and in some devices partially quantized including a series of with (n/7) × Go, steps are observed. Such an organic memory device exhibits reliable memory operation with an on/off ratio of more than 10. We attribute the quantized conductance to the existence of a 1-D electron waveguide along the conductive path. The partial quantized conductance results likely from imperfect transmission coefficient due to impedance mismatch of the first waveguide modes.