Browsing by Author "Sedighi, Alireza"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
- Applications of Motor Variability for Assessing Repetitive Occupational TasksSedighi, Alireza (Virginia Tech, 2017-06-07)The human body has substantial kinetic and kinematic degrees-of-freedoms, so redundant solutions are available for the central nervous system (CNS) to perform a repetitive task. Due to these redundancies, inherent variations exist in human movement, called motor variability (MV). Current evidence suggests that MV can be beneficial, and that there is an inverse association between MV and risk of injury. To better understand how the CNS manipulates MV to reduce injury risks, we investigated the effects of individual differences, task-relevant aspects, and psychological factors as modifiers of MV. Earlier work found that experienced workers adapted more stable movements than novices in repetitive lifting tasks. To expand on this, we quantified how MV differs between experienced workers and novices in different lifting conditions (i.e., lifting asymmetry and fatigue). Three different measures (cycle-to-cycle SD, sample entropy, and the goal equivalent manifold) were used to quantify MV. In a symmetric lifting task, experienced workers had more constrained movement than novices, and experienced workers exhibited more consistent behavior in the asymmetric condition. Novices constrained their movements, and could not maintain the same level of variability in the asymmetric condition. We concluded that experienced workers adapt stable or flexible strategies depending on task difficulty. In a prolonged lifting task, both groups increased their MV to adapt to fatigue; they particularly increased variability in a direction that had no effects on their main task goal. Developing fatigue also makes it difficult for individuals maintain the main goal. Based on these results, we conclude that increasing variability is an adaptive strategy in response to fatigue. We also assessed variability in gait parameters to compare gait adaptability using a head-worn display (HWD) compared with head-down displays for visual information presentation. An effective strategy we observed for performing a cognitive task successfully during walking was to increase gait variability in the goal direction. In addition, we found that head-up walking had smaller effects on MV, suggesting that HWDs are a promising technology to reduce adverse events during gait (e.g., falls). In summary, these results suggest that MV can be a useful indicator for evaluating some occupational injury risks.
- Exploration of different classes of metrics to characterize motor variability during repetitive symmetric and asymmetric lifting tasksSedighi, Alireza; Nussbaum, Maury A. (Springer Nature, 2019-07-08)The substantial kinematic degrees-of-freedom available in human movement lead to inherent variations in a repetitive movement, or motor variability (MV). Growing evidence suggests that characterizing MV permits a better understanding of potential injury mechanisms. Several diverse methods, though, have been used to quantify MV, but limited evidence exists regarding the merits of these methods in the occupational context. In this work, we explored different classes of methods for characterizing MV during symmetric and asymmetric box lifting tasks. Kinematic MV of both the whole-body center-of-mass (COM) and the box were quantified, using metrics derived from a linear method (Standard Deviation), a non-linear method (Sample Entropy; an index of movement regularity), and a novel application of an equifinality method (Goal Equivalent Manifold; an index related to the set of effective motor solutions). Our results suggest that individuals manipulate regularity and the set of effective motor solutions to overcome unwanted motor noises related to the COM. These results, together with earlier evidence, imply that individuals may prioritize stability over variability with increasing task difficulty. Task performance also appeared to deteriorate with decreasing variability and regularity of the COM. We conclude that diverse metrics of MV may be complimentary to reveal differences in MV.
- Information presentation through a headworn display ("smart glasses") has a smaller influence on the temporal structure of gait variability during dual-task gait compared to handheld displays (paper-based system and smartphone)Sedighi, Alireza; Ulman, Sophia M.; Nussbaum, Maury A. (PLOS, 2018-04-09)The need to complete multiple tasks concurrently is a common occurrence both daily life and in occupational activities, which can often include simultaneous cognitive and physical demands. As one example, there is increasing availability of head-worn display technologies that can be employed when a user is mobile (e.g., while walking). This new method of information presentation may, however, introduce risks of adverse outcomes such as a decrement to gait performance. The goal of this study was thus to quantify the effects of a headworn display (i.e., smart glasses) on motor variability during gait and to compare these effects with those of other common information displays (i.e., smartphone and paper-based system). Twenty participants completed four walking conditions, as a single task and in three dual-task conditions (three information displays). In the dual-task conditions, the information display was used to present several cognitive tasks. Three different measures were used to quantify variability in gait parameters for each walking condition (using the cycle-tocycle standard deviation, sample entropy, and the ªgoal-equivalent manifoldº approach). Our results indicated that participants used less adaptable gait strategies in dual-task walking using the paper-based system and smartphone conditions compared with single-task walking. Gait performance, however, was less affected during dual-task walking with the smart glasses. We conclude that the risk of an adverse gait event (e.g., a fall) in head-down walking conditions (i.e., the paper-based system and smartphone conditions) were higher than in single-task walking, and that head-worn displays might help reduce the risk of such events during dual-task gait conditions.