Now showing 1 - 1 of 1
Results Per Page
Sort Options
- Control, Analysis, and Design of SiC-Based High-Frequency Soft-Switching Three-Phase Inverter/RectifierSon, Gibong (Virginia Tech, 2022-11-01)This dissertation presents control, analysis, and design of silicon carbide (SiC)-based critical conduction mode (CRM) high-frequency soft-switching three-phase ac-dc converters (inverter and rectifier). The soft-switching technique with SiC devices grounded in CRM makes the operation of the ac-dc converter at hundreds of kHz possible while maintaining high efficiency with high power density. This is beneficial for rapidly growing fields such as electric vehicle charging, photovoltaic (PV) systems, and uninterruptable power supplies, etc. However, for the soft-switching technique to be practically adopted to real products in the markets, there are a lot of challenges to overcome. In this dissertation, four types of the challenges are carefully studied and discussed to address them. First, the grid-tied inverters used for distributed energy resources, such as PV systems, must continue operating to deliver power to the grid, when it faces flawed grid conditions such as voltage drop and voltage rise. During abnormal grid conditions, delivering constant active power from the inverter to the grid is essential to avoid large voltage ripples on the dc side because it could trigger over-voltage protection or harm the circuitries, eventually shutting down the inverter. Hence, in such cases, unbalanced ac currents need to be injected into the grid. When the grid voltages and the ac currents are not balanced, there is a chance for the CRM soft-switching inverter to lose its soft-switching capability. Continuous conduction mode operation emerges, causing hard-switching where discontinuous conduction mode (DCM) operation is expected. This leads to huge turn-on loss and high dv/dt noise at the active switch's turn-on moment. To eradicate the hard-switching problem, two improved modulation schemes are developed; one with off-time extension in the CRM phase, the other by skipping switching pulses in the DCM phase. The DCM pulse skipping is applied for a variety of grid imbalance cases, and it is proven that it can be a generalized solution for any kinds of unbalanced grid conditions. Second, the CRM soft-switching scheme with 2-channel interleaving achieves high efficiency at heavy load. Nevertheless, the efficiency plunges as the output load is reduced. This is not suitable for PV inverters, which take account of light load efficiency in terms of "weighted efficiency". Small inductor currents at light load cause the switching frequency to soar because of its CRM-based operation characteristic, causing large switching loss. To increase the inductor current dealt with by the first channel, a phase shedding control is proposed. Gate signals for the second channel are not excited, increasing the first channel's inductor current, thus cutting down the first channel's switching frequency. To prevent the unwanted circulating current formed by shared zero-sequence voltage in the paralleled structure, only two phases in the second channel working in high frequency are shed. The proposed phase shedding control achieves a 0.5 to 3.9 % efficiency improvement with light loads. Third, due to the usage of SiC devices, high dv/dt generated at switching nodes over the system parasitic capacitance causes substantial common mode (CM) noise compared to that with Si devices. In this case, a balance technique with PCB winding inductors can effectively reduce the CM noise. First, winding interleaving structure is selected to minimize the eddy current loss in the windings. But the interwinding capacitance caused by the winding interleaving structure aggravates the CM noise. Impact of the interwinding capacitance on the CM noise is analyzed with a new inductor model containing the interwinding capacitance. Then, finally, a novel inductor structure is proposed to remove the interwinding capacitance and to improve the CM noise reduction performance. The soft-switching ac-dc converter built with the final PCB magnetics features almost similar efficiency compared to that with litz-wire inductor and 14 to 18 dB CM noise reduction up to 15 MHz. Lastly, the soft-switching technique is extended to inverters in standalone mode. To meet tight ac voltage total harmonic distortion requirements, a current control in dq-frame is introduced. As for the ac voltage regulation at no-load, on top of the improved phase shedding control, a frequency limiting with fixed frequency DCM method is applied to prevent excessive increase in the switching frequency. Then, how to deal with short-circuit at the output load is investigated. Since the soft-switching modulation violates inductor voltage-second balance during the short-circuit, the modulation method is switched to a conventional sinusoidal PWM at fixed frequency. It is concluded that all the additional requirements for the standalone inverters can be satisfied by the introduced control strategies.