Browsing by Author "Thacker, Timothy Neil"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- Control of Power Conversion Systems for the Intentional Islanding of Distributed Generation UnitsThacker, Timothy Neil (Virginia Tech, 2005-09-26)Within the past decade, talk has arisen of shifting the utility grid from centralized, radial sources to a distributed network of sources, also known as distributed generation (DG); in the wake of deregulation, the California energy crisis, and northeastern blackouts. Existing control techniques for DG systems are designed to operate a system either in the connected or disconnected (islanding) mode to the utility; thus not allowing for both modes to be implemented and transitioned between. Existing detection and re-closure algorithms can also be improved upon. Dependent upon the method implemented, detection algorithms can either cause distortions in the output or completely miss a disturbance. The present re-closure process to reconnect to the utility is to completely shutdown and wait five minutes. The proposed methods of this study improve upon existing methods, via simulation and hardware experimentation, for DG systems that can intentionally islanding themselves. The proposed, "switched-mode", control allows for continuous operation of the system during disturbances by transitioning the mode of control to reflect the change in the system mode (grid-connected or islanding). This allows for zero downtimes without detrimental transients. The proposed detection method can sense disturbances that other methods cannot; and within 25 ms (approximately 1.5 line-cycles at 60 Hz). This method is an improvement over other methods because it eliminates the need to purposely distort the outputs to sense a disturbance. The proposed re-closure method is an improvement over the existing method due to the fact that it does not require the system to de-energize before re-synchronizing and reconnecting to the utility. This allows for DGs to continuously supply power to the system without having to shut down. Results show that the system is generally ready to reconnect after 2 to 5 line cycles.
- Phase-Locked Loops, Islanding Detection and Microgrid Operation of Single-Phase Converter SystemsThacker, Timothy Neil (Virginia Tech, 2009-09-16)Within recent years, interest in the installation of solar-based, wind-based, and various other renewable Distributed Energy Resources (DERs) and Energy Storage (ES) systems has risen; in part due to rising energy costs, demand for cleaner power generation, increased power quality demands, and the need for additional protection against brownouts and blackouts. A viable solution for these requirements consists of installation of small-scale DER and ES systems at the single-phase (1Φ) distribution level to provide ancillary services such as peak load shaving, Static-VAr Compensation (STATCOM), ES, and Uninterruptable Power Supply (UPS) capabilities through the creation of microgrid systems. To interconnect DER and ES systems, power electronic converters are needed with not only control systems that operate in multiple modes of operation, but with islanding detection and resynchronization capabilities for isolation from and reclosure to the grid. The proposed system includes control architecture capable of operating in multiple modes, and with the ability to smoothly transfer between modes. Phase-Locked Loops (PLLs), islanding detection schemes, and resynchronization protocols are developed to support the control functionality proposed. Stationary frame PLL developments proposed in this work improve upon existing methods by eliminating steady-state noise/ripple without using Low-Pass Filters (LPFs), increasing frequency/phase tracking speeds for a wide range of disturbances, and retaining robustness for weakly interconnected systems. An islanding detection scheme for the stationary frame control is achieved through the stability of the PLL system interaction with the converter control. The proposed detection method relies upon the conditional stability of the PLL controller which is sensitive to grid-disconnections. This method is advantageous over other methods of active islanding detection mainly due to the need for those methods to perturb the output to test for islanding conditions. The PLL stability method does not inject signal perturbations into the output of the converter, but instead is designed to be stable while grid-connected, but inherently unstable for grid-disconnections. Resynchronization and reclosure to the grid is an important control aspect for microgrid systems that have the ability to operate in stand-alone, backup modes while disconnected from the grid. The resynchronization method proposed utilizes a dual PLL tracking system which minimizes voltage transients during the resynchronization process; while a logic-based reclosure algorithm ensures minimal magnitude, frequency, and phase mismatches between the grid and an isolated microgrid system to prevent inrush currents between the grid and stand-alone microgrid system.