Browsing by Author "Williams, Krista"
Now showing 1 - 4 of 4
Results Per Page
Sort Options
- Chlorine Disinfection of Legionella spp., L. pneumophila, and Acanthamoeba under Warm Water Premise Plumbing ConditionsMartin, Rebekah L.; Harrison, Kara; Proctor, Caitlin R.; Martin, Amanda; Williams, Krista; Pruden, Amy; Edwards, Marc A. (MDPI, 2020-09-22)Premise plumbing conditions can contribute to low chlorine or chloramine disinfectant residuals and reactions that encourage opportunistic pathogen growth and create risk of Legionnaires’ Disease outbreaks. This bench-scale study investigated the growth of Legionella spp. and Acanthamoeba in direct contact with premise plumbing materials—glass-only control, cross-linked polyethylene (PEX) pipe, magnesium anode rods, iron pipe, iron oxide, pH 10, or a combination of factors. Simulated glass water heaters (SGWHs) were colonized by Legionella pneumophila and exposed to a sequence of 0, 0.1, 0.25, and 0.5 mg/L chlorine or chloramine, at two levels of total organic carbon (TOC), over 8 weeks. Legionella pneumophila thrived in the presence of the magnesium anode by itself and or combination with other factors. In most cases, 0.5 mg/L Cl2 caused a significant rapid reduction of L. pneumophila, Legionella spp., or total bacteria (16S rRNA) gene copy numbers, but at higher TOC (>1.0 mg C/L), a chlorine residual of 0.5 mg/L Cl2 was not effective. Notably, Acanthamoeba was not significantly reduced by the 0.5 mg/L chlorine dose.
- Critical Review: Propensity of Premise Plumbing Pipe Materials to Enhance or Diminish Growth of Legionella and Other Opportunistic PathogensCullom, Abraham C.; Martin, Rebekah L.; Song, Yang; Williams, Krista; Williams, Amanda; Pruden, Amy; Edwards, Marc A. (MDPI, 2020-11-17)Growth of Legionella pneumophila and other opportunistic pathogens (OPs) in drinking water premise plumbing poses an increasing public health concern. Premise plumbing is constructed of a variety of materials, creating complex environments that vary chemically, microbiologically, spatially, and temporally in a manner likely to influence survival and growth of OPs. Here we systematically review the literature to critically examine the varied effects of common metallic (copper, iron) and plastic (PVC, cross-linked polyethylene (PEX)) pipe materials on factors influencing OP growth in drinking water, including nutrient availability, disinfectant levels, and the composition of the broader microbiome. Plastic pipes can leach organic carbon, but demonstrate a lower disinfectant demand and fewer water chemistry interactions. Iron pipes may provide OPs with nutrients directly or indirectly, exhibiting a high disinfectant demand and potential to form scales with high surface areas suitable for biofilm colonization. While copper pipes are known for their antimicrobial properties, evidence of their efficacy for OP control is inconsistent. Under some circumstances, copper’s interactions with premise plumbing water chemistry and resident microbes can encourage growth of OPs. Plumbing design, configuration, and operation can be manipulated to control such interactions and health outcomes. Influences of pipe materials on OP physiology should also be considered, including the possibility of influencing virulence and antibiotic resistance. In conclusion, all known pipe materials have a potential to either stimulate or inhibit OP growth, depending on the circumstances. This review delineates some of these circumstances and informs future research and guidance towards effective deployment of pipe materials for control of OPs.
- Relationship between Organic Carbon and Opportunistic Pathogens in Simulated Glass Water HeatersWilliams, Krista; Pruden, Amy; Falkinham, Joseph O. III; Edwards, Marc A. (MDPI, 2015-06-09)Controlling organic carbon levels in municipal water has been hypothesized to limit downstream growth of bacteria and opportunistic pathogens in premise plumbing (OPPPs). Here, the relationships between influent organic carbon (0–15,000 µg ozonated fulvic acid /L) and the number of total bacteria [16S rRNA genes and heterotrophic plate counts (HPCs)] and a wide range of OPPPs (gene copy numbers of Acanthamoeba polyphaga, Vermamoeba vermiformis, Legionella pneumophila, and Mycobacterium avium) were examined in the bulk water of 120-mL simulated glass water heaters (SGWHs). The SGWHs were operated at 32–37 °C, which is representative of conditions encountered at the bottom of electric water heaters, with water changes of 80% three times per week to simulate low use. This design presented advantages of controlled and replicated (triplicate) conditions and avoided other potential limitations to OPPP growth in order to isolate the variable of organic carbon. Over seventeen months, strong correlations were observed between total organic carbon (TOC) and both 16S rRNA gene copy numbers and HPC counts (avg. R2 > 0.89). Although M. avium gene copies were occasionally correlated with TOC (avg. R2 = 0.82 to 0.97, for 2 out of 4 time points) and over a limited TOC range (0–1000 µg/L), no other correlations were identified between other OPPPs and added TOC. These results suggest that reducing organic carbon in distributed water is not adequate as a sole strategy for controlling OPPPs, although it may have promise in conjunction with other approaches.
- Relationship Between Organic Carbon and Opportunistic Pathogens in Simulated Premise Plumbing SystemsWilliams, Krista (Virginia Tech, 2011-08-04)Consumer exposure to opportunistic pathogens in potable water systems poses a significant challenge to public health as manifested by numerous cases of pneumonia, non-tuberculosis lung disease, and keratitis eye infections. Water utilities have extensive understanding in control of heterotrophic and coliform bacteria re-growth in water distribution systems via disinfection, control of assimilable organic carbon (AOC), and biologically degradable organic carbon (BDOC). However, much little is known about the effect of AOC on the proliferation of heterotrophic bacteria and pathogens within premise plumbing. This thesis is the first systematic examination of opportunistic pathogen persistence and amplification in simulated glass water heaters (SGWH) as a function of influent organic matter concentration. The role of plumbing conditions that may internally generate AOC is critically examined as part of this evaluation. Strong correlations were often observed between influent organic matter and heterotrophic bacteria in effluent of SGWH as indicated by 16S rRNA gene abundance (average R2 value of 0.889 and 0.971 for heterotrophic organisms and 16S rRNA respectively). The correlation was strongest if water turnover was more frequent (every 48-72 hours) and decreased markedly when water changes were less frequent (stagnation up to 7 days). No simple correlations were identified between the concentration of pathogenic bacteria (L. pneumophila, M. avium, A. polyphaga, and H. vermiformis) and AOC, although correlations were observed between M. avium and TOC over a limited range (and only for a subset of experiments). Indeed, there was little evidence that Legionella and Acanthamoeba proliferated under any of the conditions tested in this work. Parallel experiments were conducted to examine the extent to which factors present in premise plumbing (e.g. sacrificial magnesium anode rods, cross-linked polyethylene, nitrifying bacteria, and iron) could influence water chemistry and influence growth of bacteria or specified pathogens. Although these factors could strongly influence pH, dissolved oxygen concentrations, and levels of organic matter (e.g. iron, magnesium, nitrifying), there was no major impact on effluent concentrations of either heterotrophic bacteria or premise plumbing pathogens under the conditions investigated. While additional research is needed to confirm these findings, at present, there is no evidence of correlations between organic matter and pathogen concentrations from SGWH under conditions tested. Substantial effort was also invested in attempting to identify SGWH and oligotrophic nutrient conditions that would consistently support L. pneumophila and A. polyphaga amplification. A review of the literature indicates no prior examples of large scale amplification of these microorganisms at nutrient levels commonly found in synthesized potable water. It is likely that a complex combination of abiotic and biotic factors (i.e. micronutrients, necrotrophic growth, ambient water temperature, disinfectant type and dose, plumbing materials, water usage patterns), which are not yet fully understood, control the amplification and viability of these pathogenic organisms in premise plumbing systems.