Browsing by Author "Wong, David"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- Effects of Bit Chewing on Gastric Emptying, Small Intestinal Transit, and Orocecal Transit Times in Clinically Normal HorsesPatton, Molly E.; Andrews, Frank M.; Bogers, Sophie Helen; Wong, David; McKenzie, Harold C.; Werre, Stephen R.; Byron, Christopher R. (MDPI, 2023-08-04)Ileus is a common life-threatening problem in horses, and currently available treatments may be ineffective. The purpose of this study was to determine whether bit chewing, a form of sham feeding, decreases the gastric emptying time (GET), small intestinal transit time (SITT), and total orocecal transit time (OCTT) in clinically normal horses in a prospective crossover study. Nine healthy horses were acclimated and fed a standardized diet. Following 24 h of fasting, self-contained video endoscopy capsules and acetaminophen were administered into the stomach via a nasogastric tube. Each horse underwent experimental (bit chewing for 20 min every 6 h) or control (no bit chewing) conditions, with a 3-week minimum washout period between conditions. The horses were enrolled in either part of the study until all video capsules were retrieved and/or 30 days lapsed. The video capsules were recovered from manure, and GET, SITT, and OCTT were determined from a video analysis. Bit chewing significantly decreased OCTT (p = 0.015) compared to the control conditions. Bit chewing decreased GET and SITT, but the differences were not significant. The mean (median) times determined via the video capsule analysis for the bit-chewing conditions were as follows: GET, 2.34 h (2.86 h); SITT, 3.22 h (3.65 h); and OCTT, 5.13 h (6.15 h), and for the control conditions, they were as follows: GET, 3.93 h (5 h); SITT, 3.79 h (4.4 h); and OCTT, 8.02 h (9.92 h). Bit chewing decreased OCTT in healthy horses. Because this segment of the gastrointestinal tract is frequently affected by ileus, bit chewing may be a safe and inexpensive intervention for that condition in horses. Further investigation in clinical patients with ileus is warranted.
- Evaluation of a continuous glucose monitoring system in neonatal foalsWong, David; Malik, Caitlin; Dembek, Katarzyna; Estell, Krista; Marchitello, Megan; Wilson, Katie (2021-07)Background Monitoring blood glucose concentrations is common in critically ill neonatal foals, especially septic foals and those receiving naso-esophageal feedings or IV parenteral nutrition. Glucose typically is measured using a point-of-care (POC) glucometer but requires repeated restraint and blood collections, which may cause irritation at venipuncture sites and increased demands on nursing staff. Continuous glucose monitoring systems (CGMS) may provide an accurate alternative for monitoring blood glucose concentration. Objectives To determine the correlation and accuracy of a CGMS to monitor neonatal foals' blood glucose concentrations as compared to a POC glucometer and laboratory chemistry analysis (CHEM). Animals Samples from 4 healthy and 4 ill neonatal foals. Methods A CGMS was placed on each foal, and glucose measurements acquired from this device were compared to simultaneous measurements of blood glucose concentration using a POC glucometer and CHEM. Results Two-hundred matched glucose measurements were collected from 8 neonatal foals. The mean bias (95% limits of agreement) between CGMS and CHEM, CGMS and POC glucometer, and POC glucometer and CHEM was 3.97 mg/dL (-32.5 to 40.4), 18.2 mg/dL (-28.8 to 65.2), and 22.18 mg/dL (-9.3 to 53.67), respectively. The Pearson's correlation coefficient (r) was significantly correlated among all devices: GCMS and CHEM (r = 0.81), CGMS and POC glucometer (r = 0.77) and POC glucometer-CHEM (r = 0.92). Conclusions and Clinical Importance Within the blood glucose concentration ranges in this study (78-212 mg/dL), CGMS measurements were significantly correlated with CHEM, suggesting that it is an acceptable method to provide meaningful, immediate, and continuous glucose concentration measurements in neonatal foals while eliminating the need for repeated restraint and blood collection.