Browsing by Author "Yao, Wenchuo"
Now showing 1 - 4 of 4
Results Per Page
Sort Options
- Assessing Human Exposure to Emissions from Ultrasonic HumidifiersYao, Wenchuo (Virginia Tech, 2021-09-14)Portable ultrasonic humidifiers add moisture into room air, but they simultaneously add exposure risks of aerosolized metals from drinking water used as fill water. The inhalation exposure from emitted metals can be overlooked, and thus, co-exposure of inhalation and ingestion and co-exposure to multiple inorganic metals is investigated. The objectives of this work are: 1) predict airborne metal concentrations and particle sizes in four realistic room scenarios (33 m3 small or 72 m3 large, with varying ventilation rates from 0.2/hr -1.5/hr), and the investigated metals are arsenic, cadmium, chromium, copper, lead, and manganese; 2) characterize exposure doses and consequent risks for adults and 0.25, 1, 2.5, and 6 yr old children, when using identical drinking water ingested and as fill water, including inhalation of fine, respirable particles generated at the frequency of 8 hrs/day (equals 121.67 days/yr) and daily ingestion, under four realistic room scenarios. The risk assessment includes non-cancer [calculation of average daily dose (ADD) and hazard quotient (HQ)] and cancer risk evaluation; 3) quantify deposition fraction and deposited doses of multiple metals in human adult's and children's respiratory tract, using multi-path particle dosimetry (MPPD) model. Results show airborne-particle-bound metal concentrations increase proportionally with water metals, and a poorly ventilated room causes greater exposure. Ingestion ADDs are 2 magnitudes higher than inhalation ADD, at identical water metal concentrations and daily exposure frequency. However, in the worse-case scenario of 33 m3 small room with low air exchange rate, the consequent inhalation HQs are all greater than 1 for children and adults, except for lead, indicating significant non-cancer risks when exposed to humidifier particles under the worse-case scenario. The cancer risks for arsenic, cadmium, chromium, and lead metals reveal are greater than acceptable one case in a million population (1E-6) produced from inhalation of the humidifier emitted metal-containing particles only. The MPPD model results indicate inhaled metal-containing airborne particles deposit primarily in head and pulmonary regions, and a greater dose (unit in µg/kg body weight/day) deposits in children than adults. Inhalation of ultrasonic humidifier aerosolized metals results in additional, and potentially greater risks (indicated by HQinhalation >1, and greater deposited dose) than ingestion at the same aqueous metal concentration, especially for children. Room conditions (i.e. volume and ventilation) influence risks. Both inhalation and ingestion exposures require consideration for eliminating multiple metal exposures and health-based environmental policy making. Consumers should be aware that they may be degrading their indoor air quality by using ultrasonic humidifiers even when filling with acceptable water quality for drinking.
- Emission of Insoluble Mineral Particles from Ultrasonic HumidifiersYao, Wenchuo (Virginia Tech, 2018-01-10)Ultrasonic humidifier use is a potential source of human exposure to inhalable particulates. This paper focused on the behavior of insoluble iron oxides particles, and aluminum oxide particles in ultrasonic humidifiers. 10 mg/L Fe oxide particles and 5 mg/L Al oxide suspension solutions were added into tap water, as fill water for ultrasonic humidifiers operated for 14 hours. Denser, heavier particles of approximate 1.5 um diameter of iron or aluminum oxides accumulated in the humidifier reservoir. Smaller, suspended metal oxide particles of 0.22-0.57 um diameter were emitted as aerosols from humidifiers. Soluble anions and cations in tap water were present in the aerosols emitted from humidifiers. The results indicate that if suspended particles and dissolved minerals are present in source water, they will be transported in aerosolized waters.
- Exposure at the indoor water–air interface: Fill water constituents and the consequent air emissions from ultrasonic humidifiers: A systematic reviewDietrich, Andrea M.; Yao, Wenchuo; Gallagher, Daniel L. (Wiley, 2022-11-01)This systematic review investigates the emissions from ultrasonic humidifiers (e.g., cool mist humidifiers) within indoor air environments, namely soluble and insoluble metals and minerals as well as microorganisms and one organic chemical biocide. Relationships between ultrasonic humidifier fill water quality and the emissions in indoor air are studied, and associated potential adverse health outcomes are discussed. Literature from January 1, 1980, to February 1, 2022, was searched from online databases of PubMed, Web of Science, and Scopus to produce 27 articles. The results revealed clear positive proportional relationships of the concentration of microorganisms and soluble metals/minerals between fill water qualities and emitted airborne particles, for both microbial (n = 9) and inorganic (n = 15) constituents. When evaluating emissions and the consequent health outcomes, ventilation rates of specific exposure scenarios affect the concentrations of emitted particles. Thus, well-ventilated rooms may alleviate inhalation risks when the fill water in ultrasonic humidifiers contains microorganisms and soluble metals/minerals. Case reports (n = 3) possibly due to the inhalation of particles from ultrasonic humidifier include hypersensitivity pneumonitis in adults and a 6-month infant; the young infant exhibited nonreversible mild obstructive ventilator defect. In summary, related literature indicated correlation between fill water quality of ultrasonic humidifier and emitted particles in air quality, and inhalation of the emitted particles may cause undesirable health outcomes of impaired respiratory functions in adults and children.
- An overlooked route of inhalation exposure to tap water constituents for children and adults: Aerosolized aqueous minerals from ultrasonic humidifiersYao, Wenchuo; Gallagher, Daniel L.; Dietrich, Andrea M. (Elsevier, 2020-12-01)Fine particulates and aerosols emitted by commonly used, room-sized ultrasonic humidifiers may pose adverse health effects to children and adults. The literature documents adverse effects for children exposed to minerals emitted from humidifiers. This study performs novel and comprehensive characterization of bivariate particle size and element concentrations of emitted airborne aerosols and particles from ultrasonic humidifiers filled with tap water, including size distribution from 0.014 to 10 μm by scanning mobility particle sizer and AeroTrak; corresponding metal and elemental concentrations as a function of particle size by inductively coupled plasma mass spectrometer; and calculations of deposition fraction in human lungs for age-specific groups using the multi-path particle dosimetry model (MPPD). Deposition fraction is the ratio of mass deposited to total mass inhaled. When filled with tap water, water evaporated from emitted aerosols to form submicron particles that became essentially “dried tap water” with median size 146 nm and mean concentration of 211 μg-total elements/m3-air including 35 μg-calcium/m3-air in a room of 33.5 m3 and air exchange rate at ∼0.8 hr−1. Approximately 90% of emitted particles deposited in human lungs were <1 μm as shown by MPPD model. The smaller particles contained little water and higher concentration of minerals, while larger particles of >1 μm consisted of lower elemental concentrations and more water due to low evaporation. Deposition fraction in pulmonary region was ∼2-fold higher, and deposited particulate mass was 3.5-fold higher for children than adults, indicating greater inhalation exposure to children compared to adults. Modeled data of total particles mass per body weight (BW) that will deposit in adult and child lungs after 8-h humidifier exposure were respectively 2.8 μg/kg-BW and 9.8 μg/kg-BW, where calcium contributes 0.4 μg/kg-BW and 1.6 μg/kg-BW. This comprehensive study of bivariate inorganic chemical composition as a function of particle size expanded, quantified, and modeled exposure for children and adults to aerosolized calcium and other inorganic constituents in water.