Scholarly Works, Industrial and Systems Engineering
Permanent URI for this collection
Research articles, presentations, and other scholarship
Browse
Browsing Scholarly Works, Industrial and Systems Engineering by Department "School of Biomedical Engineering and Sciences"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
- Evaluation of Two Approaches for Aligning Data Obtained from a Motion Capture System and an In-Shoe Pressure Measurement SystemKim, Sunwook; Nussbaum, Maury A. (MDPI, 2014-09-12)An in-shoe pressure measurement (IPM) system can be used to measure center of pressure (COP) locations, and has fewer restrictions compared to the more conventional approach using a force platform. The insole of an IPM system, however, has its own coordinate system. To use an IPM system along with a motion capture system, there is thus a need to align the coordinate systems of the two measurement systems. To address this need, the current study examined two different approaches—rigid body transformation and nonlinear mapping (i.e., multilayer feed-forward neural network (MFNN))—to express COP measurements from an IPM system in the coordinate system of a motion capture system. Ten participants (five male and five female) completed several simulated manual material handling (MMH) activities, and during these activities the performance of the two approaches was assessed. Results indicated that: (1) performance varied between MMH activity types; and (2) a MFNN performed better than or comparable to the rigid body transformation, depending on the specific input variable sets used. Further, based on the results obtained, it was argued that a nonlinear mapping vs. rigid body transformation approach may be more effective to account for shoe deformation during MMH or potentially other types of physical activity.
- Load-Relaxation Properties of the Human Trunk in Response to Prolonged Flexion: Measuring and Modeling the Effect of Flexion AngleToosizadeh, Nima; Nussbaum, Maury A.; Bazrgari, Babak; Madigan, Michael L. (PLOS, 2012-11-05)Experimental studies suggest that prolonged trunk flexion reduces passive support of the spine. To understand alterations of the synergy between active and passive tissues following such loadings, several studies have assessed the time-dependent behavior of passive tissues including those within spinal motion segments and muscles. Yet, there remain limitations regarding load-relaxation of the lumbar spine in response to flexion exposures and the influence of different flexion angles. Ten healthy participants were exposed for 16 min to each of five magnitudes of lumbar flexion specified relative to individual flexion-relaxation angles (i.e., 30, 40, 60, 80, and 100%), during which lumbar flexion angle and trunk moment were recorded. Outcome measures were initial trunk moment, moment drop, parameters of four viscoelastic models (i.e., Standard Linear Solid model, the Prony Series, Schapery's Theory, and the Modified Superposition Method), and changes in neutral zone and viscoelastic state following exposure. There were significant effects of flexion angle on initial moment, moment drop, changes in normalized neutral zone, and some parameters of the Standard Linear Solid model. Initial moment, moment drop, and changes in normalized neutral zone increased exponentially with flexion angle. Kelvin-solid models produced better predictions of temporal behaviors. Observed responses to trunk flexion suggest nonlinearity in viscoelastic properties, and which likely reflected viscoelastic behaviors of spinal (lumbar) motion segments. Flexion-induced changes in viscous properties and neutral zone imply an increase in internal loads and perhaps increased risk of low back disorders. Kelvin-solid models, especially the Prony Series model appeared to be more effective at modeling load-relaxation of the trunk.
- Preferred Placement and Usability of a Smart Textile System vs. Inertial Measurement Units for Activity MonitoringMokhlespour Esfahani, Mohammad Iman; Nussbaum, Maury A. (MDPI, 2018-08-01)Wearable sensors and systems have become increasingly popular in recent years. Two prominent wearable technologies for human activity monitoring are smart textile systems (STSs) and inertial measurement units (IMUs). Despite ongoing advances in both, the usability aspects of these devices require further investigation, especially to facilitate future use. In this study, 18 participants evaluate the preferred placement and usability of two STSs, along with a comparison to a commercial IMU system. These evaluations are completed after participants engaged in a range of activities (e.g., sitting, standing, walking, and running), during which they wear two representatives of smart textile systems: (1) a custom smart undershirt (SUS) and commercial smart socks; and (2) a commercial whole-body IMU system. We first analyze responses regarding the usability of the STS, and subsequently compared these results to those for the IMU system. Participants identify a short-sleeved shirt as their preferred activity monitor. In additional, the SUS in combination with the smart socks is rated superior to the IMU system in several aspects of usability. As reported herein, STSs show promise for future applications in human activity monitoring in terms of usability.