    Experimental Investigation of the Multiple Row Extended 1/2 End-Plate Moment Connection

    Thumbnail
    View/Open
    MBMA_9911.pdf (2.927Mb)
    Downloads: 2235
    Date
    2001-12-01
    Author
    Sumner, Emmett A.
    Murray, Thomas M.
    Metadata
    Show full item record
    Abstract
    End-plate moment connections are widely used by the low-rise metal building industry to provide the rigid connections necessary in gable frames. There are numerous end-plate moment connection configurations. The multiple row extended 1/2 (MRE 112) end-plate moment connection configuration is the focus of this investigation. The MRE 1/2 end-plate moment connection has three rows of bolts at the tension flange, one row located outside the beam flange and two rows located inside the beam flange. Six MRE 1/2 end-plate moment connection tests were conducted at the Virginia Tech Structures and Materials Laboratory. The purpose of the tests was to investigate the moment strength of the connections and to validate the current design procedures. Details of the connection design, test set-up, testing procedure, and test results are presented within this report. It is concluded that the current design procedures, presented in the forthcoming AISC Steel Design Guide 16, Flush and Extended Multiple Row Moment End-Plate Connections (Murray and Shoemaker, 2002), conservatively predict the strength of MRE 112 end-plate moment connections. The strength predictions are adequate for MRE 1/2 end-plate connections utilizing A325 or A490 bolts with a standard or a large inner pitch distance.
    URI
    http://hdl.handle.net/10919/24199
    Collections
    • Virginia Tech Structural Engineering and Materials Report Series [24]

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us
     

     

    VTechWorks

    AboutPoliciesHelp

    Browse

    All of VTechWorksCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Log inRegister

    Statistics

    View Usage Statistics

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us