Exact Interior Reconstruction from Truncated Limited-Angle Projection Data

dc.contributor.authorYe, Yangboen
dc.contributor.authorYu, Hengyongen
dc.contributor.authorWang, Geen
dc.contributor.departmentSchool of Biomedical Engineering and Sciencesen
dc.date.accessioned2017-09-18T10:02:54Zen
dc.date.available2017-09-18T10:02:54Zen
dc.date.issued2008-05-06en
dc.date.updated2017-09-18T10:02:54Zen
dc.description.abstractUsing filtered backprojection (FBP) and an analytic continuation approach, we prove that exact interior reconstruction is possible and unique from truncated limited-angle projection data, if we assume a prior knowledge on a subregion or subvolume within an object to be reconstructed. Our results show that (i) the interior region-of-interest (ROI) problem and interior volume-of-interest (VOI) problem can be exactly reconstructed from a limited-angle scan of the ROI/VOI and a 180 degree PI-scan of the subregion or subvolume and (ii) the whole object function can be exactly reconstructed from nontruncated projections from a limited-angle scan. These results improve the classical theory of Hamaker et al. (1980).en
dc.description.versionPublished versionen
dc.format.mimetypeapplication/pdfen
dc.identifier.citationYangbo Ye, Hengyong Yu, and Ge Wang, “Exact Interior Reconstruction from Truncated Limited-Angle Projection Data,” International Journal of Biomedical Imaging, vol. 2008, Article ID 427989, 6 pages, 2008. doi:10.1155/2008/427989en
dc.identifier.doihttps://doi.org/10.1155/2008/427989en
dc.identifier.urihttp://hdl.handle.net/10919/79060en
dc.language.isoenen
dc.publisherHindawien
dc.rightsCreative Commons Attribution 4.0 Internationalen
dc.rights.holderCopyright © 2008 Yangbo Ye et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.en
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en
dc.titleExact Interior Reconstruction from Truncated Limited-Angle Projection Dataen
dc.title.serialInternational Journal of Biomedical Imagingen
dc.typeArticle - Refereeden
dc.type.dcmitypeTexten

Files

Original bundle
Now showing 1 - 2 of 2
Name:
IJBI.2008.427989.xml
Size:
6.36 KB
Format:
Extensible Markup Language
Loading...
Thumbnail Image
Name:
IJBI.2008.427989.pdf
Size:
702.3 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.5 KB
Format:
Item-specific license agreed upon to submission
Description: