Varying Collimation for Dark-Field Extraction

dc.contributor.authorWang, Geen
dc.contributor.authorCong, Wenxiangen
dc.contributor.authorShen, Haiouen
dc.contributor.authorZou, Yuen
dc.contributor.departmentSchool of Biomedical Engineering and Sciencesen
dc.date.accessioned2017-09-18T09:59:40Zen
dc.date.available2017-09-18T09:59:40Zen
dc.date.issued2010-02-16en
dc.date.updated2017-09-18T09:59:40Zen
dc.description.abstractAlthough x-ray imaging is widely used in biomedical applications, biological soft tissues have small density changes, leading to low contrast resolution for attenuation-based x-ray imaging. Over the past years, x-ray small-angle scattering was studied as a new contrast mechanism to enhance subtle structural variation within the soft tissue. In this paper, we present a detection method to extract this type of x-ray scattering data, which are also referred to as dark-field signals. The key idea is to acquire an x-ray projection multiple times with varying collimation before an x-ray detector array. The projection data acquired with a collimator of a sufficiently high collimation aspect ratio contain mainly the primary beam with little scattering, while the data acquired with an appropriately reduced collimation aspect ratio include both the primary beam and small-angle scattering signals. Then, analysis of these corresponding datasets will produce desirable dark-field signals; for example, via digitally subtraction. In the numerical experiments, the feasibility of our dark-field detection technology is demonstrated in Monte Carlo simulation. The results show that the acquired dark field signals can clearly reveal the structural information of tissues in terms of Rayleigh scattering characteristics.en
dc.description.versionPublished versionen
dc.format.mimetypeapplication/pdfen
dc.identifier.citationGe Wang, Wenxiang Cong, Haiou Shen, and Yu Zou, “Varying Collimation for Dark-Field Extraction,” International Journal of Biomedical Imaging, vol. 2009, Article ID 847537, 7 pages, 2009. doi:10.1155/2009/847537en
dc.identifier.doihttps://doi.org/10.1155/2009/847537en
dc.identifier.urihttp://hdl.handle.net/10919/79049en
dc.language.isoenen
dc.publisherHindawien
dc.rightsCreative Commons Attribution 4.0 Internationalen
dc.rights.holderCopyright © 2009 Ge Wang et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.en
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en
dc.titleVarying Collimation for Dark-Field Extractionen
dc.title.serialInternational Journal of Biomedical Imagingen
dc.typeArticle - Refereeden
dc.type.dcmitypeTexten

Files

Original bundle
Now showing 1 - 2 of 2
Name:
IJBI.2009.847537.xml
Size:
14.28 KB
Format:
Extensible Markup Language
Loading...
Thumbnail Image
Name:
IJBI.2009.847537.pdf
Size:
2.43 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.5 KB
Format:
Item-specific license agreed upon to submission
Description: