Single Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiography

dc.contributor.authorVorpahl, Marcen
dc.contributor.authorKoehler, Tillen
dc.contributor.authorFoerst, Jason R.en
dc.contributor.authorPanagiotopoulos, Spyridonen
dc.contributor.authorSchleiting, Heinrichen
dc.contributor.authorKoss, Klausen
dc.contributor.authorZiegler, Gundaen
dc.contributor.authorBrinkmann, Hilmaren
dc.contributor.authorSeyfarth, Melchioren
dc.contributor.authorTiroch, Klausen
dc.date.accessioned2017-09-18T09:40:49Zen
dc.date.available2017-09-18T09:40:49Zen
dc.date.issued2015-09-08en
dc.date.updated2017-09-18T09:40:49Zen
dc.description.abstractCurrent guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, ). Fluoroscopy time was comparable between CONV and TIG, without crossover ( min versus  min; n.s.), however, greater in the case of crossover for CONV () and TIG (; ). Radiation dosage was similar in CONV and the TIG, without crossover (, cGycm2 versus ; n.s.), however, greater for CONV () and TIG (, ) with crossover. Overall, the amount of contrast was greater in TIG ( mL) versus CONV ( mL; ). CONV femoral catheters may be the primary choice for radial approach.en
dc.description.versionPublished versionen
dc.format.mimetypeapplication/pdfen
dc.identifier.citationMarc Vorpahl, Till Koehler, Jason Foerst, et al., “Single Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiography,” Cardiology Research and Practice, vol. 2015, Article ID 862156, 6 pages, 2015. doi:10.1155/2015/862156en
dc.identifier.doihttps://doi.org/10.1155/2015/862156en
dc.identifier.urihttp://hdl.handle.net/10919/78955en
dc.language.isoenen
dc.publisherHindawien
dc.rightsCreative Commons Attribution 4.0 Internationalen
dc.rights.holderCopyright © 2015 Marc Vorpahl et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.en
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en
dc.titleSingle Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiographyen
dc.title.serialCardiology Research and Practiceen
dc.typeArticle - Refereeden
dc.type.dcmitypeTexten

Files

Original bundle
Now showing 1 - 2 of 2
Name:
CRP.2015.862156.xml
Size:
13.02 KB
Format:
Extensible Markup Language
Loading...
Thumbnail Image
Name:
CRP.2015.862156.pdf
Size:
1.03 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.5 KB
Format:
Item-specific license agreed upon to submission
Description: