Impact of Fume Hood Retrofits on the Energy Performance of Laboratory Spaces

dc.contributor.authorReichard, Georgen
dc.contributor.authorPriya, Shashanken
dc.date.accessioned2019-08-14T18:03:39Zen
dc.date.available2019-08-14T18:03:39Zen
dc.date.issued2014-09en
dc.description.abstractThere are probably more than a million fume hoods operated in laboratories throughout the United States. Most of these fume hoods still run under more or less continuous conditions and thus consume an enormous amount of energy per year. There seems to be a significant savings potential if the total exhausted volumes could be reduced while all safety requirements are met. Researchers have meanwhile developed and identified high-performance fume hood solutions that could facilitate a reduction of up to 75% of the consumed energy required to condition make-up air. However, most of these solutions are geared towards new construction as they require specific spatial and system design configurations. There is a lack of knowledge regarding retrofit options and their expected savings potential on energy consumption for existing laboratories. Since fume hoods interact with other systems and fulfill design requirements that are already in place, any modification will consequently impact other performance requirements within the same environment. This project set out to gain a broader understanding of direct and indirect impacts of various retrofit scenarios for individual fume hoods, their integrated function within a laboratory space, and their overall impact on energy consumption of a space.en
dc.description.sponsorshipNational Energy Management Institute Committee (NEMIC)en
dc.identifier.urihttp://hdl.handle.net/10919/93138en
dc.identifier.urlhttps://bestlab.mlsoc.vt.edu/sites/bestlab/files/upload/publications/Executive%20Report.pdfen
dc.language.isoen_USen
dc.publisherVirginia Tech. Myers Lawson School of Constructionen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.titleImpact of Fume Hood Retrofits on the Energy Performance of Laboratory Spacesen
dc.typeReporten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Executive Report.pdf
Size:
832.05 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.5 KB
Format:
Item-specific license agreed upon to submission
Description: