Metal-ceramic laminate composite magnetoelectric gradiometer

Files

TR Number

Date

2010-03-01

Journal Title

Journal ISSN

Volume Title

Publisher

AIP Publishing

Abstract

Gradiometer resembles in functionality a magnetic field sensor where it measures the magnetic field gradient and its sensitivity is determined by the ability to quantify differential voltage change with respect to a reference value. Magnetoelectric (ME) gradiometer designed in this study is based upon the nickel (Ni)-Pb(Zr,Ti)O(3) (PZT) composites and utilizes the ring-dot piezoelectric transformer structure working near the resonance as the basis. The samples had the ring-dot electrode pattern printed on the top surface of PZT, where ring acts as the input while dot acts as the output. There is an insulation gap between the input and output section of 1.2 mm. The generated magnetic field due to converse ME effect interacts with the external applied magnetic field producing flux gradient, which is detected through the frequency shift and output voltage change in gradiometer structure. The measurements of output voltage dependence on applied magnetic field clearly illustrate that the proposed design can provide high sensitivity and bandwidth.

Description

Keywords

Ceramics, Laminates, Magnetic field measurement, Magnetic sensors, Magnetoelectronics, Magnetometers

Citation

Bedekar, V.; Bichurin, M. I.; Ivanov, S. N.; et al., "Metal-ceramic laminate composite magnetoelectric gradiometer," Rev. Sci. Instrum. 81, 033906 (2010); http://dx.doi.org/10.1063/1.3354985