Method to correct the distortion caused by amplified stimulated emission as motivated by LIF-based flow diagnostics

dc.contributorVirginia Techen
dc.contributor.authorLi, Xuesongen
dc.contributor.authorZhao, Yanen
dc.contributor.authorMa, Linen
dc.contributor.departmentAerospace and Ocean Engineeringen
dc.date.accessed2014-02-06en
dc.date.accessioned2014-03-14T15:04:25Zen
dc.date.available2014-03-14T15:04:25Zen
dc.date.issued2012-04-01en
dc.description.abstractAmplified stimulated emission (ASE) represents a significant issue in two-photon laser-induced fluorescence (TPLIF). The ASE effects are nonlinear and nonlocal, i.e., the ASE effects distort the LIF signal nonlinearly, and the distortion at one location depends on conditions at other locations. In this sense, the ASE effects pose a greater challenge to quantitative TPLIF than quenching and ionization. This work therefore seeks a method to correct such distortion. The method uses two LIF measurements, one with low signal-to-noise ratio (SNR) and negligible ASE distortion and another with high SNR but significant distortion, to generate a faithful measurement with high SNR. Extensive simulations were performed to evaluate the performance of this method for practical applications. c 2012 Optical Society of America OCIS codes: 300.2530, 300.6420, 120.1740.en
dc.description.sponsorshipNational Science Foundation CBET 0844939en
dc.identifier.citationXuesong Li, Yan Zhao, and Lin Ma, "Method to correct the distortion caused by amplified stimulated emission as motivated by LIF-based flow diagnostics," Appl. Opt. 51, 2107-2117 (2012); doi: 10.1364/AO.51.002107en
dc.identifier.doihttps://doi.org/10.1364/AO.51.002107en
dc.identifier.issn1559-128Xen
dc.identifier.urihttp://hdl.handle.net/10919/25896en
dc.identifier.urlhttp://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-51-12-2107en
dc.language.isoen_USen
dc.publisherOptical Society of Americaen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectLaser-induced fluorescenceen
dc.subjectAtomic oxygenen
dc.subjectPhotodissociationen
dc.subjectSpectroscopyen
dc.subject2-photon excitationen
dc.subjectMixture fractionen
dc.subjectFlamesen
dc.subjectHydrogenen
dc.subjectVisualizationen
dc.subjectPlasmaen
dc.subjectGasesen
dc.titleMethod to correct the distortion caused by amplified stimulated emission as motivated by LIF-based flow diagnosticsen
dc.title.serialApplied Opticsen
dc.typeArticle - Refereeden
dc.type.dcmitypeTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ao-51-12-2107.pdf
Size:
1.07 MB
Format:
Adobe Portable Document Format
Description:
Main article