Filtration evaluation and clinical use of expired elastomeric P-100 filter cartridges during the COVID-19 pandemic

dc.contributor.authorPatolia, Harsh H.en
dc.contributor.authorPan, Jinen
dc.contributor.authorHarb, Charbelen
dc.contributor.authorMarr, Linsey C.en
dc.contributor.authorBaffoe-Bonnie, Anthony W.en
dc.contributor.departmentCivil and Environmental Engineeringen
dc.contributor.departmentVirginia Tech Carilion School of Medicineen
dc.date.accessioned2020-06-08T12:58:07Zen
dc.date.available2020-06-08T12:58:07Zen
dc.date.issued2020-05-27en
dc.description.abstractTo the Editor—The limited supply of more conventional disposable personal protective equipment (PPE), namely single-use N95 filtering facepiece respirators (FFRs), among hospital systems in the United States during the COVID-19 pandemic has been alleviated with the adoption of extended use and reuse policies by the Centers for Disease Control and Prevention (CDC).1 These measures, along with a variety of implemented decontamination methodologies (eg, ultraviolet germicidal irradiation, vaporized hydrogen peroxide, etc), have prolonged PPE supplies during pressing times. Another strategy adopted by the CDC and health systems to protect healthcare providers caring for COVID-19 patients and patients under investigation in limited resource settings includes the use of elastomeric FFRs with reusable cartridges. Although elastomeric respirators have not been approved by the Food and Drug Administration for fluid resistance, they have been endorsed by the CDC as reasonable alternatives for N95 FFRs during the COVID-19 pandemic due to their filtration approval by the National Institutes for Occupational and Safety Health (NIOSH).2 Subsequently, elastomeric respirators have formed a major arm of the COVID-19 pandemic response strategy in many hospital systems...en
dc.format.mimetypeapplication/pdfen
dc.identifier.doihttps://doi.org/10.1017/ice.2020.257en
dc.identifier.urihttp://hdl.handle.net/10919/98777en
dc.language.isoenen
dc.publisherCambridge University Pressen
dc.rightsCreative Commons Attribution 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en
dc.titleFiltration evaluation and clinical use of expired elastomeric P-100 filter cartridges during the COVID-19 pandemicen
dc.title.serialInfection Control & Hospital Epidemiologyen
dc.typeArticleen
dc.type.dcmitypeTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PatoliaFiltration.pdf
Size:
205.06 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.5 KB
Format:
Item-specific license agreed upon to submission
Description: