The PMU placement problem
Files
TR Number
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
PMU placement problem is an optimization problem abstracted from an approach to supervising an electrical power system. The power system is modeled as a graph, and adequate supervision of the system requires that the voltage at each node and the current through each edge be observable. A phasor measurement unit ( PMU) is a monitor that can be placed at a node to directly observe the voltage at that node, as well as the current and its phase through all incident edges. The PMU placement problem is to place PMUs at a minimum number of nodes so that the entire electric power system is observed. A new simpler definition of graph observability and several complexity results for the PMU placement problem are presented. The PMU placement problem is shown to be NP-complete even for planar bipartite graphs. Several fundamental properties of PMU placements are proven, including the property that a minimum PMU placement requires no more than 1/3 of the nodes in a connected graph of at least 3 nodes.