Ultrasonic water measurement in irrigation pipelines with disturbed flow
dc.contributor | Virginia Tech | en |
dc.contributor.author | Johnson, A. L. | en |
dc.contributor.author | Benham, Brian L. | en |
dc.contributor.author | Eisenhauer, D. E. | en |
dc.contributor.author | Hotchkiss, R. H. | en |
dc.contributor.department | Biological Systems Engineering | en |
dc.date.accessed | 2014-05-29 | en |
dc.date.accessioned | 2014-05-30T13:13:50Z | en |
dc.date.available | 2014-05-30T13:13:50Z | en |
dc.date.issued | 2001 | en |
dc.description.abstract | Ultrasonicflow meter accuracy was investigated over a range of flow conditions (3 pipe materials, 2 pipe sizes, 4 Reynolds numbers, 7 flow-disturbing devices) commonly found in irrigation systems. Flow rate measurements were taken at five locations downstream from a flow disturbance. The measurement accuracy was within +/-5% of actual flow at a minimum of 10 pipe diameters downstream from the flow disturbances. Errors as high as 36.5% occurred when measurements were taken close to some flow disturbances. A multiplier was developed to correct for directional bias for devices that fell into the Group I category (single elbow, two elbows, check valve, and 50% open butterfly valve with vertical and horizontal orientation). Applying the multiplier at 4.5 pipe diameters and higher resulted in accuracies within +/-4% of actual flow. The regression analysis performed on Group I devices showed that the USFM performance was not significantly different for the three pipe materials, two pipe diameters, and four flow rates. | en |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Johnson, A. L.; Benham, B. L.; Eisenhauer, D. E.; Hotchkiss, R. H., " Ultrasonic water measurement in irrigation pipelines with disturbed flow," Transactions of the ASAE. Vol. 44(4): 899-910. (doi: 10.13031/2013.6254) @2001 | en |
dc.identifier.doi | https://doi.org/10.13031/2013.6254 | en |
dc.identifier.issn | 0001-2351 | en |
dc.identifier.uri | http://hdl.handle.net/10919/48213 | en |
dc.identifier.url | http://elibrary.asabe.org/abstract.asp?aid=6254&t=3&dabs=Y&redir=&redirType= | en |
dc.language.iso | en | en |
dc.publisher | American Society of Agricultural and Biological Engineers | en |
dc.rights | In Copyright | en |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | en |
dc.subject | Ultrasonic measurement system | en |
dc.subject | Water measurement | en |
dc.subject | Irrigation pipeline | en |
dc.subject | Metering | en |
dc.subject | Agricultural engineering | en |
dc.title | Ultrasonic water measurement in irrigation pipelines with disturbed flow | en |
dc.title.serial | Transactions of the ASAE | en |
dc.type | Article - Refereed | en |