Browsing by Author "Lee, Wah-Keat"
Now showing 1 - 7 of 7
Results Per Page
Sort Options
- Burst mode pumping: A new mechanism of drinking in mosquitoesKikuchi, Kenji; Stremler, Mark A.; Chatterjee, Souvick; Lee, Wah-Keat; Mochizuki, Osamu; Socha, John J. (Nature Publishing Group, 2018-03-20)Mosquitoes transport liquid foods into the body using two muscular pumps in the head. In normal drinking, these pumps reciprocate in a stereotyped pattern of oscillation, with a high frequency but small stroke volume. Do mosquitoes modulate their neuromotor programs for pumping to produce different drinking modes? More broadly, what are the mechanical consequences of a two-pump system in insects? To address these questions, we used synchrotron x-ray imaging and fluid mechanical modeling to investigate drinking performance in mosquitoes. X-ray imaging of the pumps during drinking revealed two modes of pumping: continuous reciprocation with multiple small strokes, and a newly discovered ‘burst mode’ involving a single, large-volume stroke. Results from modeling demonstrate that burst mode pumping creates a very large pressure drop and high volume flow rate, but requires a massive increase in power, suggesting that continuous pumping is more economical for drinking. Modeling also demonstrates that, from one mode of pumping to the other, the mechanical role of the individual pumps changes. These results suggest that the advantage of a two-pump system in insects lies in its flexibility, enabling the animal to pump efficiently or powerfully as demanded by environmental considerations.
- Direct visualization of hemolymph flow in the heart of a grasshopper (Schistocerca americana)Lee, Wah-Keat; Socha, John J. (BMC, 2009-03-09)Background: Hemolymph flow patterns in opaque insects have never been directly visualized due to the lack of an appropriate imaging technique. The required spatial and temporal resolutions, together with the lack of contrast between the hemolymph and the surrounding soft tissue, are major challenges. Previously, indirect techniques have been used to infer insect heart motion and hemolymph flow, but such methods fail to reveal fine-scale kinematics of heartbeat and details of intra-heart flow patterns. Results: With the use of microbubbles as high contrast tracer particles, we directly visualized hemolymph flow in a grasshopper (Schistocerca americana) using synchrotron x-ray phase-contrast imaging. In-vivo intra-heart flow patterns and the relationship between respiratory (tracheae and air sacs) and circulatory (heart) systems were directly observed for the first time. Conclusion: Synchrotron x-ray phase contrast imaging is the only generally applicable technique that has the necessary spatial, temporal resolutions and sensitivity to directly visualize heart dynamics and flow patterns inside opaque animals. This technique has the potential to illuminate many long-standing questions regarding small animal circulation, encompassing topics such as retrograde heart flow in some insects and the development of flow in embryonic vertebrates.
- Flow Measurements in a Blood-Perfused Collagen Vessel Using X-Ray Micro-Particle Image VelocimetryAntoine, Elizabeth E.; Buchanan, Cara; Fezzaa, Kamel; Lee, Wah-Keat; Rylander, M. Nichole; Vlachos, Pavlos P. (2013-11-18)Blood-perfused tissue models are joining the emerging field of tumor engineering because they provide new avenues for modulation of the tumor microenvironment and preclinical evaluation of the therapeutic potential of new treatments. The characterization of fluid flow parameters in such in-vitro perfused tissue models is a critical step towards better understanding and manipulating the tumor microenvironment. However, traditional optical flow measurement methods are inapplicable because of the opacity of blood and the thickness of the tissue sample. In order to overcome the limitations of optical method we demonstrate the feasibility of using phase-contrast x-ray imaging to perform microscale particle image velocimetry (PIV) measurements of flow in blood perfused hydrated tissue-representative microvessels. However, phase contrast x-ray images significantly depart from the traditional PIV image paradigm, as they have high intensity background, very low signal-to-noise ratio, and volume integration effects. Hence, in order to achieve accurate measurements special attention must be paid to the image processing and PIV cross-correlation methodologies. Therefore we develop and demonstrate a methodology that incorporates image preprocessing as well as advanced PIV cross-correlation methods to result in measured velocities within experimental uncertainty.
- Hypoxia-induced compression in the tracheal system of the tobacco hornworm caterpillar, Manduca sextaGreenlee, Kendra J.; Socha, John J.; Eubanks, Haleigh B.; Pedersen, Paul; Lee, Wah-Keat; Kirkton, Scott D. (Company of Biologists Ltd., 2013-06-01)Abdominal pumping in caterpillars has only been documented during molting. Using synchrotron X-ray imaging in conjunction with high-speed flow-through respirometry, we show that Manduca sexta caterpillars cyclically contract their bodies in response to hypoxia, resulting in significant compressions of the tracheal system. Compression of tracheae induced by abdominal pumping drives external gas exchange, as evidenced by the high correlation between CO2 emission peaks and body movements. During abdominal pumping, both the compression frequency and fractional change in diameter of tracheae increased with body mass. However, abdominal pumping and tracheal compression were only observed in larger, older caterpillars (>0.2.g body mass), suggesting that this hypoxic response increases during ontogeny. The diameters of major tracheae in the thorax increased isometrically with body mass. However, tracheae in the head did not scale with mass, suggesting that there is a large safety margin for oxygen delivery in the head in the youngest animals. Together, these results highlight the need for more studies of tracheal system scaling and suggest that patterns of tracheal investment vary regionally in the body.
- Synchrotron X-Ray Visualisation of Ice Formation in Insects during Lethal and Non-Lethal FreezingSinclair, Brent J.; Gibbs, Allen G.; Lee, Wah-Keat; Rajamohan, Arun; Roberts, Stephen P.; Socha, John J. (PLOS, 2009-12-14)Although the biochemical correlates of freeze tolerance in insects are becoming well-known, the process of ice formation in vivo is subject to speculation. We used synchrotron x-rays to directly visualise real-time ice formation at 3.3 Hz in intact insects. We observed freezing in diapausing 3rd instar larvae of Chymomyza amoena (Diptera: Drosophilidae), which survive freezing if it occurs above −14°C, and non-diapausing 3rd instar larvae of C. amoena and Drosophila melanogaster (Diptera: Drosophilidae), neither of which survive freezing. Freezing was readily observed in all larvae, and on one occasion the gut was seen to freeze separately from the haemocoel. There were no apparent qualitative differences in ice formation between freeze tolerant and non-freeze tolerant larvae. The time to complete freezing was positively related to temperature of nucleation (supercooling point, SCP), and SCP declined with decreasing body size, although this relationship was less strong in diapausing C. amoena. Nucleation generally occurred at a contact point with the thermocouple or chamber wall in non-diapausing larvae, but at random in diapausing larvae, suggesting that the latter have some control over ice nucleation. There were no apparent differences between freeze tolerant and non-freeze tolerant larvae in tracheal displacement or distension of the body during freezing, although there was markedly more distension in D. melanogaster than in C. amoena regardless of diapause state. We conclude that although control of ice nucleation appears to be important in freeze tolerant individuals, the physical ice formation process itself does not differ among larvae that can and cannot survive freezing. This suggests that a focus on cellular and biochemical mechanisms is appropriate and may reveal the primary adaptations allowing freeze tolerance in insects.
- Transmission x-ray microscopy and its applications in battery material research-a short reviewSpence, Stephanie; Lee, Wah-Keat; Lin, Feng; Xiao, Xianghui (IOP, 2021-10-29)Transmission x-ray microscopy (TXM), which can provide morphological and chemical structural information inside of battery component materials at tens of nanometer scale, has become a powerful tool in battery research. This article presents a short review of the TXM, including its instrumentation, battery research applications, and the practical sample preparation and data analysis in the TXM applications. A brief discussion on the challenges and opportunities in the TXM applications is presented at the end.
- TXM-Sandbox: an open-source software for transmission X-ray microscopy data analysisXiao, Xianghui; Xu, Zhengrui; Lin, Feng; Lee, Wah-Keat (International Union of Crystallography, 2022-01)A transmission X-ray microscope (TXM) can investigate morphological and chemical information of a tens to hundred micrometre-thick specimen on a length scale of tens to hundreds of nanometres. It has broad applications in material sciences and battery research. TXM data processing is composed of multiple steps. A workflow software has been developed that integrates all the tools required for general TXM data processing and visualization. The software is written in Python and has a graphic user interface in Jupyter Notebook. Users have access to the intermediate analysis results within Jupyter Notebook and have options to insert extra data processing steps in addition to those that are integrated in the software. The software seamlessly integrates ImageJ as its primary image viewer, providing rich image visualization and processing routines. As a guide for users, several TXM specific data analysis issues and examples are also presented.