Virginia Tech
    • Log in
    View Item 
    •   VTechWorks Home
    • ETDs: Virginia Tech Electronic Theses and Dissertations
    • Doctoral Dissertations
    • View Item
    •   VTechWorks Home
    • ETDs: Virginia Tech Electronic Theses and Dissertations
    • Doctoral Dissertations
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Design, Analysis, and Testing of Nanoparticle-Infused Thin Film Sensors for Low Skin Friction Applications

    Thumbnail
    View/Open
    Leslie_BR_D_2012.pdf (17.49Mb)
    Downloads: 1499
    Date
    2012-12-07
    Author
    Leslie, Brian Robert
    Metadata
    Show full item record
    Abstract
    Accurate measurement of skin friction in complex flows is important for: documentation and monitoring of fluid system performance, input information for flow control, development of turbulence models and CFD validation. The goal of this study was to explore using new materials to directly measure skin friction in a more convenient way than available devices. Conventional direct measurement skin friction sensors currently in use are intrusive, requiring movable surface elements with gaps surrounding that surface, or require optical access for measurements. Conventional direct measurement sensors are also difficult to apply in low shear environments, in the 1-10 Pa range. A new thin, flexible, nanoparticle infused, piezoresistive material called Metal Rubber" was used to create sensors that can be applied to any surface. This was accomplished by using modern computerized finite element model multiphysics simulations of the material response to surface shear loads, in order to design a sensor configuration with a reduced footprint, minimal cross influence and increased sensitivity. These sensors were then built, calibrated in a fully-developed water channel flow and tested in both the NASA 20x28 inch Shear Flow Control Tunnel and a backwards facing step water flow. The results from these tests showed accurate responses, with no amplification to the sensor output, to shear levels in the range of 1-15 Pa. In addition, the computer model of these sensors was found to be useful for studying and developing refined sensor designs and for documenting sources of measurement uncertainty. These encouraging results demonstrate the potential of this material for skin friction sensor applications.
    URI
    http://hdl.handle.net/10919/19199
    Collections
    • Doctoral Dissertations [16334]

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us
     

     

    VTechWorks

    AboutPoliciesHelp

    Browse

    All of VTechWorksCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Log inRegister

    Statistics

    View Usage Statistics

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us