Evaluation of UV Disinfection Performance in Recirculating Systems

dc.contributor.authorZhu, S.en
dc.contributor.authorSaucier, B. B.en
dc.contributor.authorChen, S.en
dc.contributor.authorDurfey, J. E.en
dc.contributor.editorSmith, Stephen Allenen
dc.date.accessioned2019-06-25T16:55:03Zen
dc.date.available2019-06-25T16:55:03Zen
dc.date.issued2002-06-01en
dc.description.abstractThe use of ultraviolet (UV) disinfection devices has become increasingly popular in wastewater and aquaculture industries. Although the effectiveness of UV disinfection has been well documented for flowthrough operation regimes in wastewater treatment, research focusing on water recirculating systems is still limited. In this study, the performance of single-lamp UV devices were tested on a recirculating system for fecal coliform (FC) disinfection. Experimental results indicated that UV power input, recirculating flow rate and water UV transmittance were three important factors determining UV disinfection efficiency. An UV disinfection model for a recirculating system was developed based on theoretical analysis and experimental data. A key model parameter, namely the first-order inactivation rate constant (k), was determined to be 0.0062 m2 J-1 for FC disinfection. Simulation using the model provided useful information for design and operation of recirculating UV disinfection systems. The model prediction of disinfection process for other microorganisms is also capable of using reported values of the inactivation rate constant.en
dc.format.extent18 pagesen
dc.format.extent1.07 MBen
dc.format.mimetypeapplication/pdfen
dc.identifier.citationZhu, S., Saucier, B.B., Chen, S. and Durfey, J.E., 2002. Evaluation of UV Disinfection Performance in Recirculating Systems. International Journal of Recirculating Aquaculture, 3. DOI: http://doi.org/10.21061/ijra.v3i1.1458en
dc.identifier.doihttps://doi.org/10.21061/ijra.v3i1.1458en
dc.identifier.eissn2572-9160en
dc.identifier.issn1547-917Xen
dc.identifier.issue1en
dc.identifier.urihttp://hdl.handle.net/10919/90587en
dc.identifier.volume3en
dc.language.isoenen
dc.publisherCommercial Fish and Shellfish Technologies Program, Virginia Techen
dc.rightsIn Copyrighten
dc.rights.holderCommercial Fish and Shellfish Technologies Program, Virginia Techen
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectUV Disinfectionen
dc.subjectRecirculating Aquaculture Systemsen
dc.titleEvaluation of UV Disinfection Performance in Recirculating Systemsen
dc.title.serialInternational Journal of Recirculating Aquacultureen
dc.typeArticle - Refereeden
dc.type.dcmitypeTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
v3-zhu.pdf
Size:
1.07 MB
Format:
Adobe Portable Document Format