Correlations between the thermal vibrations of two cantilevers: Validation of deterministic analysis via the fluctuation-dissipation theorem

dc.contributorVirginia Techen
dc.contributor.authorHonig, Christopher D. F.en
dc.contributor.authorRadiom, Miladen
dc.contributor.authorRobbins, Brian A.en
dc.contributor.authorWalz, John Y.en
dc.contributor.authorPaul, Mark R.en
dc.contributor.authorDucker, William A.en
dc.contributor.departmentMechanical Engineeringen
dc.contributor.departmentChemical Engineeringen
dc.date.accessed2014-01-10en
dc.date.accessioned2014-01-21T19:28:03Zen
dc.date.available2014-01-21T19:28:03Zen
dc.date.issued2012-02-01en
dc.description.abstractWe validate a theoretical approach for analyzing correlations in the fluctuations of two cantilevers in terms of a deterministic model, using the fluctuation-dissipation theorem [M. R. Paul and M. C. Cross, Phys. Rev. Lett. 92, 235501 (2004)]. The validation has been made possible through measurement of the correlations between the thermally stimulated vibrations of two closely spaced micrometer-scale cantilevers in fluid. Validation of the theory enables development of a method for characterizing fluids, which we call correlation force spectrometry. (C) 2012 American Institute of Physics. [doi:10.1063/1.3681141]en
dc.identifier.citationHonig, Christopher D. F.; Radiom, Milad; Robbins, Brian A.; et al., "Correlations between the thermal vibrations of two cantilevers: Validation of deterministic analysis via the fluctuation-dissipation theorem," Appl. Phys. Lett. 100, 053121 (2012); http://dx.doi.org/10.1063/1.3681141en
dc.identifier.doihttps://doi.org/10.1063/1.3681141en
dc.identifier.issn0003-6951en
dc.identifier.urihttp://hdl.handle.net/10919/24923en
dc.identifier.urlhttp://scitation.aip.org/content/aip/journal/apl/100/5/10.1063/1.3681141en
dc.language.isoen_USen
dc.publisherAIP Publishingen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectAtomic force microscopyen
dc.subjectStochastic dynamicsen
dc.subjectFrequency-responseen
dc.subjectFluidsen
dc.subjectPhysicsen
dc.titleCorrelations between the thermal vibrations of two cantilevers: Validation of deterministic analysis via the fluctuation-dissipation theoremen
dc.title.serialApplied Physics Lettersen
dc.typeArticle - Refereeden
dc.type.dcmitypeTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1.3681141.pdf
Size:
975.98 KB
Format:
Adobe Portable Document Format
Description:
Main article