Practical Current Derivation Method for a Highly Accurate Variable Switching Frequency ZVS regulation in TCM operated Bidirectional Buck/Boost Converters

dc.contributor.authorGutierrez, Bryanen
dc.contributor.authorHou, Zhengmingen
dc.contributor.authorJiao, Dongen
dc.contributor.authorLai, Jih-Shengen
dc.date.accessioned2026-02-25T18:04:22Zen
dc.date.available2026-02-25T18:04:22Zen
dc.date.issued2024en
dc.description.abstractTriangular conduction mode (TCM) is a technique to operate non-isolated buck/boost converters under zero voltage switching (ZVS) turn-on. In TCM, a negative current is required for the active device to turn on under ZVS condition. The magnitude of this current is well-known and established. However, the derivation of the variable switching frequency according to the operating condition is usually simplified with the linear character of the magnetization and demagnetization of the inductors in the converter. The utilization of this simplification can increase the peak-to-peak current ripple in the inductor and burden the duty cycle loss in the controller. Additionally, it can increase the turn-off loss in the devices. This paper presents a highly accurate computation for the variable switching frequency to reduce the negative effects of the simplified method. Derivations are presented for charging and discharging modes, and they were tested in a 15-kW rated bidirectional dual-phase buck-boost converter.en
dc.description.versionSubmitted versionen
dc.format.extentPages 2054-2058en
dc.format.extent5 page(s)en
dc.format.mimetypeapplication/pdfen
dc.identifier.doihttps://doi.org/10.1109/APEC48139.2024.10509229en
dc.identifier.issn1048-2334en
dc.identifier.orcidLai, Jih [0000-0003-2315-8460]en
dc.identifier.urihttps://hdl.handle.net/10919/141570en
dc.language.isoenen
dc.publisherIEEEen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectbidirectional dc-dc converteren
dc.subjecttriangularen
dc.subjectconduction mode (TCM)en
dc.subjectvariable switching frequencyen
dc.subjectzerovoltageen
dc.subjectswitching (ZVS)en
dc.titlePractical Current Derivation Method for a Highly Accurate Variable Switching Frequency ZVS regulation in TCM operated Bidirectional Buck/Boost Convertersen
dc.title.serial2024 IEEE Applied Power Electronics Conference and Exposition, APECen
dc.typeConference proceedingen
dc.type.dcmitypeTexten
dc.type.otherProceedings Paperen
dc.type.otherBook in seriesen
pubs.finish-date2024-02-29en
pubs.organisational-groupVirginia Techen
pubs.organisational-groupVirginia Tech/Engineeringen
pubs.organisational-groupVirginia Tech/Engineering/Electrical and Computer Engineeringen
pubs.organisational-groupVirginia Tech/All T&R Facultyen
pubs.organisational-groupVirginia Tech/Engineering/COE T&R Facultyen
pubs.start-date2024-02-25en

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2023344508.pdf
Size:
614.69 KB
Format:
Adobe Portable Document Format
Description:
Submitted version
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.5 KB
Format:
Plain Text
Description: