Development and characterization of a hydrogen peroxide sensor using catalase immobilized on a pyroelectric poly(vinylidene flouride) film

dc.contributor.authorArney, Lawrence Hinkleen
dc.contributor.committeechairDessy, Raymond E.en
dc.contributor.committeememberWolfe, James F.en
dc.contributor.committeememberMason, John G.en
dc.contributor.committeememberLong, Gary L.en
dc.contributor.committeememberGlanville, James O.en
dc.contributor.departmentChemistryen
dc.date.accessioned2015-11-06T20:57:31Zen
dc.date.available2015-11-06T20:57:31Zen
dc.date.issued1989en
dc.description.abstractThis dissertation describes the design, development and results of a simple, inexpensive, rugged, pyroelectric heat-of-reaction detector that can be made in many configurations. The measured heat of reaction results from the reaction of a substrate on an enzyme. The enzyme is immobilized in a flow channel with a pyroelectric polymer film, poly(vinylidene fluoride) or PVDF. The sample is introduced into the flow channel using flow injection analysis technology. The heat from the reaction causes the pyroelectric material to produce an electrical potential proportional to the change in temperature which, in turn, is proportional to the substrate concentration. This potential is amplified and recorded. A differential instrument amplifier produces a difference signal from a sample and reference PVDF film. This removes noise caused by stray electromagnetic radiation and piezoelectric pressure responses. A conventional Flow Injection Analysis unit was employed. The FIA flow rate was four ml/min and the time from injection to peak maximum was less than three seconds, with a return to baseline of less than thirty seconds. This gives a quick analysis time and a reasonable number of analyses per unit time. Data interpretation is straight forward, peak height is proportional to the concentration. A 70 μl sample gives a good response. Larger samples do not improve the signal. The system showed minimum detectable number of moles that is comparable to other methods, 7 x 10⁻⁸ moles. The detector showed good response for more than two orders of magnitude. The results show excellent correlation to the modeled system of heat trans+er through the PVDF sensor.en
dc.description.degreePh. D.en
dc.format.extentxiv, 171 leavesen
dc.format.mimetypeapplication/pdfen
dc.identifier.urihttp://hdl.handle.net/10919/63985en
dc.language.isoen_USen
dc.publisherVirginia Polytechnic Institute and State Universityen
dc.relation.isformatofOCLC# 20439218en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V856 1989.A764en
dc.subject.lcshReactivity (Chemistry) -- Researchen
dc.subject.lcshChemical detectors -- Researchen
dc.titleDevelopment and characterization of a hydrogen peroxide sensor using catalase immobilized on a pyroelectric poly(vinylidene flouride) filmen
dc.typeDissertationen
dc.type.dcmitypeTexten
thesis.degree.disciplineChemistryen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.leveldoctoralen
thesis.degree.namePh. D.en

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LD5655.V856_1989.A764.pdf
Size:
4.26 MB
Format:
Adobe Portable Document Format