Flexural Strength of Exterior Metal Building Wall Assemblies with Rigid Insulation

Files

TR Number

Date

2011-08-01

Journal Title

Journal ISSN

Volume Title

Publisher

Virginia Polytechnic Institute and State University

Abstract

The goal of this research study is to observe and quantify the influence of rigid board insulation on through-fastened girt capacity. Rotational restraint tests are performed to study local rotational stiffness at the flange-insulation contact point. Vacuum box tests on through-fastened wall systems are conducted to explore the effect of insulation thickness on the R-factor. The results will be used to support new code language in AISI S100-07 D6.1 that accommodate capacity prediction of metal building wall systems with rigid board insulation.

Description

53 p. : col. ill.

Keywords

Flexural strength, Exterior metal building wall assemblies, Rigid insulation, Through-fastened girt capacity, Rigid board insulation

Citation

Gao, T., and Moen, C.D. (2011). "Flexural Strength of Exterior Metal Building Wall Assemblies with Rigid Insulation." Virginia Tech Research Report No. CE/VPI-ST-11/01, Blacksburg, VA. (http://www.moen.cee.vt.edu/postedfiles/MBMA_rigid_board_VT_final_small.pdf)