Flexural Strength of Exterior Metal Building Wall Assemblies with Rigid Insulation

dc.contributor.authorGao, Tianen
dc.contributor.departmentCivil and Environmental Engineeringen
dc.date.accessioned2012-06-14T18:29:49Zen
dc.date.available2012-06-14T18:29:49Zen
dc.date.issued2011-08-01en
dc.description53 p. : col. ill.en
dc.description.abstractThe goal of this research study is to observe and quantify the influence of rigid board insulation on through-fastened girt capacity. Rotational restraint tests are performed to study local rotational stiffness at the flange-insulation contact point. Vacuum box tests on through-fastened wall systems are conducted to explore the effect of insulation thickness on the R-factor. The results will be used to support new code language in AISI S100-07 D6.1 that accommodate capacity prediction of metal building wall systems with rigid board insulation.en
dc.format.mimetypeapplication/pdfen
dc.identifier.citationGao, T., and Moen, C.D. (2011). "Flexural Strength of Exterior Metal Building Wall Assemblies with Rigid Insulation." Virginia Tech Research Report No. CE/VPI-ST-11/01, Blacksburg, VA. (http://www.moen.cee.vt.edu/postedfiles/MBMA_rigid_board_VT_final_small.pdf)en
dc.identifier.urihttp://hdl.handle.net/10919/18717en
dc.language.isoen_USen
dc.publisherVirginia Polytechnic Institute and State Universityen
dc.relation.ispartofseriesVirginia Tech Structures and Engineering Materials;CE/VPI-ST-11/01en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectFlexural strengthen
dc.subjectExterior metal building wall assembliesen
dc.subjectRigid insulationen
dc.subjectThrough-fastened girt capacityen
dc.subjectRigid board insulationen
dc.titleFlexural Strength of Exterior Metal Building Wall Assemblies with Rigid Insulationen
dc.typeTechnical reporten
dc.type.dcmitypeTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MBMA_rigid_board_VT_final_small.pdf
Size:
11.06 MB
Format:
Adobe Portable Document Format
Description:
Technical Report
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.5 KB
Format:
Item-specific license agreed upon to submission
Description: