Volumetric imaging of turbulent reactive flows at kHz based on computed tomography

dc.contributor.authorLi, Xuesongen
dc.contributor.authorMa, Linen
dc.contributor.departmentAerospace and Ocean Engineeringen
dc.date.accessioned2017-02-24T18:19:08Zen
dc.date.available2017-02-24T18:19:08Zen
dc.date.issued2014-02-21en
dc.description.abstractDiagnostics with three-dimensional (3D) spatial resolution and rapid temporal resolution have been long desired to resolve the complicated turbulence-chemistry interactions. This paper describes a method based on based on tomographic chemiluminescence (TC) to address this diagnostic need. The TC technique used multiple cameras to simultaneously record CH* chemiluminescence emitted by turbulent flames from different view angles. A 3D tomographic algorithm was then applied to reconstruct the instantaneous flame structures volumetrically. Both experimental and computational studies have been conducted to demonstrate and validate the 3D measurements. Experimental results were obtained instantaneously at kHz temporal rate, in a volume of 16 × 16 × 16 cm3, and with a spatial resolution estimated to be 2~3 mm. Computations were conducted to simulate the experimental conditions for comparison and validation.en
dc.format.mimetypeapplication/pdfen
dc.identifier.doihttps://doi.org/10.1364/OE.22.004768en
dc.identifier.issue4en
dc.identifier.urihttp://hdl.handle.net/10919/75144en
dc.identifier.volume22en
dc.language.isoen_USen
dc.publisherOSA Publishingen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.titleVolumetric imaging of turbulent reactive flows at kHz based on computed tomographyen
dc.title.serialOptics Expressen
dc.typeArticle - Refereeden
dc.type.dcmitypeTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MaVolumetric.pdf
Size:
4.18 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.5 KB
Format:
Item-specific license agreed upon to submission
Description: