Experimental and Analytical Studies of the Behavior of Cold-Formed Steel Roof Truss Elements

dc.contributor.authorNuttayasakul, Nuthapornen
dc.contributor.committeechairEasterling, William Samuelen
dc.contributor.committeememberRoberts-Wollmann, Carin L.en
dc.contributor.committeememberMurray, Thomas M.en
dc.contributor.committeememberCharney, Finley A.en
dc.contributor.committeememberSetareh, Mehdien
dc.contributor.departmentCivil Engineeringen
dc.date.accessioned2014-03-14T20:19:17Zen
dc.date.adate2005-12-01en
dc.date.available2014-03-14T20:19:17Zen
dc.date.issued2005-11-03en
dc.date.rdate2005-12-01en
dc.date.sdate2005-11-28en
dc.description.abstractCold-formed steel roof truss systems that use complex stiffener patterns in existing hat shape members for both top and bottom chord elements are a growing trend in the North American steel framing industry. When designing cold-formed steel sections, a structural engineer typically tries to improve the local buckling behavior of the cold-formed steel elements. The complex hat shape has proved to limit the negative influence of local buckling, however, distortional buckling can be the controlling mode of failure in the design of chord members with intermediate unbraced lengths. The chord member may be subjected to both bending and compression because of the continuity of the top and bottom chords. These members are not typically braced between panel points in a truss. Current 2001 North American Specifications (NAS 2001) do not provide an explicit check for distortional buckling. This dissertation focuses on the behavior of complex hat shape members commonly used for both the top and bottom chord elements of a cold-formed steel truss. The results of flexural tests of complex hat shape members are described. In addition, stub column tests of nested C-sections used as web members and full scale cold-formed steel roof truss tests are reported. Numerical analyses using finite strip and finite element procedures were developed for the complex hat shape chord member in bending to compare with experimental results. Both elastic buckling and inelastic postbuckling finite element analyses were performed. A parametric study was also conducted to investigate the factors that affect the ultimate strength behavior of a particular complex hat shape. The experimental results and numerical analyses confirmed that modifications to the 2001 North American Specification are necessary to better predict the flexural strength of complex hat shape members, especially those members subjected to distortional buckling. Either finite strip or finite element analysis can be used to better predict the flexural strength of complex hat shape members. Better understanding of the flexural behavior of these complex hat shapes is necessary to obtain efficient, safe design of a truss system. The results of these analyses will be presented in the dissertation.en
dc.description.degreePh. D.en
dc.identifier.otheretd-11282005-010902en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-11282005-010902/en
dc.identifier.urihttp://hdl.handle.net/10919/29765en
dc.publisherVirginia Techen
dc.relation.haspartETD.pdfen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectcold-formed steelen
dc.subjectelemental testen
dc.subjectfull scale testen
dc.subjectstub column testen
dc.subjectflexural testen
dc.subjectdistortional bucklingen
dc.subjectlocal bucklingen
dc.titleExperimental and Analytical Studies of the Behavior of Cold-Formed Steel Roof Truss Elementsen
dc.typeDissertationen
thesis.degree.disciplineCivil Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.leveldoctoralen
thesis.degree.namePh. D.en

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ETD.pdf
Size:
3.33 MB
Format:
Adobe Portable Document Format