Tempo-Fit Heart Rate App: Using Heart Rate Sonification As Exercise Performance Feedback

dc.contributor.authorLandry, Stevenen
dc.contributor.authorSun, Yuangjingen
dc.contributor.authorSlade, Darnishiaen
dc.contributor.authorJeon, Myounghoonen
dc.date.accessioned2025-01-09T13:16:40Zen
dc.date.available2025-01-09T13:16:40Zen
dc.date.issued2016-07en
dc.description.abstract<jats:p>Physical inactivity is a worldwide issue causing a variety of health problems. Exploring novel ways to encourage people to engage in physical activity is a topic at the forefront of research for countless stakeholders. Based upon a review of the literature, a pilot study, and exit interviews, we propose an app prototype that utilizes music tempo manipulation to guide users into a target heart rate zone during an exercise session. A study was conducted with 26 participants in a fifteenminute cycling session using different sonification mappings and combinations of audiovisual feedback based on the user’s current heart rate. Results suggest manipulating the playback speed of music in real time based on heart rate zone departures can be an effective motivational tool for increasing or decreasing activity levels of the listener. Participants vastly preferred prescriptive sonifications mappings over descriptive mappings, due to people’s natural inclination to follow the tempo of music.</jats:p>en
dc.description.versionPublished versionen
dc.format.extentPages 73-76en
dc.format.mimetypeapplication/pdfen
dc.identifier.doihttps://doi.org/10.21785/icad2016.018en
dc.identifier.orcidJeon, Myounghoon [0000-0003-2908-671X]en
dc.identifier.urihttps://hdl.handle.net/10919/123987en
dc.language.isoenen
dc.publisherThe International Community for Auditory Displayen
dc.relation.urihttps://doi.org/10.21785/icad2016.018en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.titleTempo-Fit Heart Rate App: Using Heart Rate Sonification As Exercise Performance Feedbacken
dc.title.serialProceedings of the 22nd International Conference on Auditory Display - ICAD 2016en
dc.typeConference proceedingen
dc.type.dcmitypeTexten
pubs.finish-date2016-07-07en
pubs.organisational-groupVirginia Techen
pubs.organisational-groupVirginia Tech/Engineeringen
pubs.organisational-groupVirginia Tech/Engineering/Industrial and Systems Engineeringen
pubs.organisational-groupVirginia Tech/All T&R Facultyen
pubs.organisational-groupVirginia Tech/Engineering/COE T&R Facultyen
pubs.start-date2016-07-03en

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ICAD2016_paper_18_Tempo-FitHeartRate.pdf
Size:
845.23 KB
Format:
Adobe Portable Document Format
Description:
Published version
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.5 KB
Format:
Plain Text
Description: