Recapitulation of an ion channel IV curve using frequency components

dc.contributor.authorRigby, J. R.en
dc.contributor.authorPoelzing, Stevenen
dc.contributor.departmentBiomedical Engineering and Mechanicsen
dc.contributor.departmentFralin Biomedical Research Instituteen
dc.coverage.spatialUnited Statesen
dc.date.accessioned2017-02-03T15:13:21Zen
dc.date.available2017-02-03T15:13:21Zen
dc.date.issued2011-02-08en
dc.description.abstractINTRODUCTION: Presently, there are no established methods to measure multiple ion channel types simultaneously and decompose the measured current into portions attributable to each channel type. This study demonstrates how impedance spectroscopy may be used to identify specific frequencies that highly correlate with the steady state current amplitude measured during voltage clamp experiments. The method involves inserting a noise function containing specific frequencies into the voltage step protocol. In the work presented, a model cell is used to demonstrate that no high correlations are introduced by the voltage clamp circuitry, and also that the noise function itself does not introduce any high correlations when no ion channels are present. This validation is necessary before the technique can be applied to preparations containing ion channels. The purpose of the protocol presented is to demonstrate how to characterize the frequency response of a single ion channel type to a noise function. Once specific frequencies have been identified in an individual channel type, they can be used to reproduce the steady state current voltage (IV) curve. Frequencies that highly correlate with one channel type and minimally correlate with other channel types may then be used to estimate the current contribution of multiple channel types measured simultaneously. METHODS: Voltage clamp measurements were performed on a model cell using a standard voltage step protocol (-150 to +50 mV, 5mV steps). Noise functions containing equal magnitudes of 1-15 kHz frequencies (zero to peak amplitudes: 50 or 100mV) were inserted into each voltage step. The real component of the Fast Fourier transform (FFT) of the output signal was calculated with and without noise for each step potential. The magnitude of each frequency as a function of voltage step was correlated with the current amplitude at the corresponding voltages. RESULTS AND CONCLUSIONS: In the absence of noise (control), magnitudes of all frequencies except the DC component correlated poorly (|R|<0.5) with the IV curve, whereas the DC component had a correlation coefficient greater than 0.999 in all measurements. The quality of correlation between individual frequencies and the IV curve did not change when a noise function was added to the voltage step protocol. Likewise, increasing the amplitude of the noise function also did not increase the correlation. Control measurements demonstrate that the voltage clamp circuitry by itself does not cause any frequencies above 0 Hz to highly correlate with the steady-state IV curve. Likewise, measurements in the presence of the noise function demonstrate that the noise function does not cause any frequencies above 0 Hz to correlate with the steady-state IV curve when no ion channels are present. Based on this verification, the method can now be applied to preparations containing a single ion channel type with the intent of identifying frequencies whose amplitudes correlate specifically with that channel type.en
dc.description.versionPublished versionen
dc.identifier.doihttps://doi.org/10.3791/2361en
dc.identifier.eissn1940-087Xen
dc.identifier.issue48en
dc.identifier.urihttp://hdl.handle.net/10919/74921en
dc.language.isoenen
dc.relation.urihttp://www.ncbi.nlm.nih.gov/pubmed/21339724en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectElectric Impedanceen
dc.subjectIon Channelsen
dc.subjectPatch-Clamp Techniquesen
dc.subjectSignal Processing, Computer-Assisteden
dc.subjectSpectrum Analysisen
dc.titleRecapitulation of an ion channel IV curve using frequency componentsen
dc.title.serialJournal of Visualized Experimentsen
dc.typeArticle - Refereeden
dc.type.otherResearch Support, N.I.H., Extramuralen
dc.type.otherVideo-Audio Mediaen
pubs.organisational-group/Virginia Techen
pubs.organisational-group/Virginia Tech/All T&R Facultyen
pubs.organisational-group/Virginia Tech/Faculty of Health Sciencesen
pubs.organisational-group/Virginia Tech/University Research Institutesen
pubs.organisational-group/Virginia Tech/University Research Institutes/Virginia Tech Carilion Research Instituteen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Recapitulation of an ion channel IV curve using frequency components.pdf
Size:
305.95 KB
Format:
Adobe Portable Document Format
Description:
Publisher's Version
License bundle
Now showing 1 - 1 of 1
Name:
VTUL_Distribution_License_2016_05_09.pdf
Size:
18.09 KB
Format:
Adobe Portable Document Format
Description: