Assessing Limb Symmetry using the Clinically Accessible loadsol®

dc.contributor.authorRenner, Kristen Elizaberthen
dc.contributor.committeechairQueen, Robin M.en
dc.contributor.committeememberTarazaga, Pablo Albertoen
dc.contributor.committeememberKelliher, Aislingen
dc.contributor.committeememberMoskal, Joseph T.en
dc.contributor.committeememberLeonessa, Alexanderen
dc.contributor.departmentDepartment of Biomedical Engineering and Mechanicsen
dc.date.accessioned2019-04-24T08:01:08Zen
dc.date.available2019-04-24T08:01:08Zen
dc.date.issued2019-04-23en
dc.description.abstractDecreased gait symmetry has been correlated with an increased fall risk, abnormal joint loading and decreased functional outcomes. Therefore, symmetry is focused on in the rehabilitation of many patient populations. Currently, load based symmetry is collected using expensive and immobile devices that are not clinically accessible, but there is a clinical need for an objective measure of loading symmetry during daily tasks like walking. Therefore, the purpose of this dissertation was to 1) assess the validity and reliability of the loadsol® to capture ground reaction force data, 2) use the loadsol® to determine the differences in symmetry between adults with a TKA and their healthy peers and 3) explore the potential of a commercially available biofeedback system to acutely improve gait symmetry in adults. The results of this work indicate that the loadsol® is a valid and reliable method of collecting loading measures during walking in both young and older adults. TKA patients who are 12-24 months post-TKA have lower symmetry in the weight acceptance peak force, propulsive peak force and impulse when compared to their healthy peers. Finally, a case study with four asymmetric adults demonstrated that a 10-minute biofeedback intervention with the loadsol® resulted in an acute improvement in symmetry. Future work is needed to determine the potential of this intervention to improve symmetry in patient populations and to determine whether the acute response is retained following the completion of the intervention.en
dc.description.abstractgeneralSymmetry during walking is a valuable attribute as asymmetry has been correlated with an increased fall risk and decreased mobility. Currently, load based symmetry is collected using expensive and immobile devices that are not clinically accessible. As a result, there is a critical need for a system that can objectively measure load and loading symmetry during rehabilitation and everyday tasks in a variety of settings. A new device has been developed (loadsol®) that could potentially fill this need. Before it can be used to assess and treat patients, the loadsol® needed to be assessed for accuracy and reliability in both older and younger adults and at various speeds. Then we needed to determine if the loadsol® can be used to look at the levels of symmetry in patients who have had a knee replacement compared to their healthy peers. Finally, we tested a visual biofeedback intervention with the loadsol® to see if this intervention was able to improve symmetry. We found that the loadsol® is accurate and reliable. Patients with a knee replacement were less symmetric than their age matched peers. Finally, in a small study, the visual biofeedback intervention improved symmetry during walking in a group of people with less than 90% symmetry. Future work is needed to explore the potential of this biofeedback intervention to improve symmetry in various patient populations and to determine the extent to which patients are able to retain these improvements.en
dc.description.degreeDoctor of Philosophyen
dc.format.mediumETDen
dc.identifier.othervt_gsexam:19397en
dc.identifier.urihttp://hdl.handle.net/10919/89102en
dc.publisherVirginia Techen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectGait analysisen
dc.subjectsymmetryen
dc.subjectbiofeedbacken
dc.subjectgait trainingen
dc.subjecttotal knee arthroplastyen
dc.titleAssessing Limb Symmetry using the Clinically Accessible loadsol®en
dc.typeDissertationen
thesis.degree.disciplineBiomedical Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.leveldoctoralen
thesis.degree.nameDoctor of Philosophyen

Files

Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Renner_KE_D_2019.pdf
Size:
2.82 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
Renner_KE_D_2019_support_3.pdf
Size:
297 KB
Format:
Adobe Portable Document Format
Description:
Supporting documents