VTechWorks staff will be away for the winter holidays starting Tuesday, December 24, 2024, through Wednesday, January 1, 2025, and will not be replying to requests during this time. Thank you for your patience, and happy holidays!
 

Development of a short test for the identification of aggregates causing poor concrete performance when frozen

dc.contributor.authorHsieh, Tai-Chouen
dc.contributor.departmentCivil Engineeringen
dc.date.accessioned2024-11-12T20:07:17Zen
dc.date.available2024-11-12T20:07:17Zen
dc.date.issued1967en
dc.description.abstractThe purpose of this thesis is to develop a fast, simple and economical method to separate bad from good aggregates which will undergo the freezing and thawing of natural weather conditions after incorporation in concrete. Freeze-thaw teats of air-entrained concrete specimens, teats on curing period of air-entrained concrete specimens exposed to freeze-thaw cycles, and mercury-intrusion porosimeter tests of individual aggregate particles were conducted. Several parameters have been obtained from these tests. They are: durability factors at 100 cycles, slope of curves of time vs. length change, slope of curves of temperature vs. length change, residual length change, slope of entire first freeze curve, total porosity, porosity in certain pore size range, slope of pore size distribution curve in certain pore size range, and pore modulus. A significant relationship exists between the durability factors and the slope of curves of time vs. length change, the durability factors and the slope of curves of temperature vs. length change, and the durability factors and the pore modulus. A good relationship also exists between the durability factors and the other parameters. The original goal of a quick, simple, and inexpensive method to distinguish bad from good aggregates is obtainable. Separation of bad good aggregates can be by either running freeze-thaw teats to obtain values of slope of curves of time vs. length change and values of slope of curves of temperature vs. length change or running poresimeter tests to obtain pore modulus.en
dc.description.degreePh. D.en
dc.format.extent112 leavesen
dc.format.mimetypeapplication/pdfen
dc.identifier.urihttps://hdl.handle.net/10919/121595en
dc.language.isoenen
dc.publisherVirginia Polytechnic Instituteen
dc.relation.isformatofOCLC# 40834372en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V856 1967.H75en
dc.titleDevelopment of a short test for the identification of aggregates causing poor concrete performance when frozenen
dc.typeDissertationen
dc.type.dcmitypeTexten
thesis.degree.disciplineCivil Engineeringen
thesis.degree.grantorVirginia Polytechnic Instituteen
thesis.degree.leveldoctoralen
thesis.degree.namePh. D.en

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LD5655.V856_1967.H75.pdf
Size:
7.23 MB
Format:
Adobe Portable Document Format