VTechWorks staff will be away for the Thanksgiving holiday beginning at noon on Wednesday, November 27, through Friday, November 29. We will resume normal operations on Monday, December 2. Thank you for your patience.
 

Vulvar skin temperature changes significantly during estrus in swine as determined by Digital Infrared Thermography

dc.contributor.authorClark, Sherrie G.en
dc.contributor.authorScolari, Saara C.en
dc.contributor.authorKnox, Robert V.en
dc.contributor.authorTamassia, Manoel A.en
dc.date.accessioned2016-10-17T18:41:15Zen
dc.date.available2016-10-17T18:41:15Zen
dc.date.issued2011en
dc.description.abstractObjective: To determine if changes in vulvar skin temperature (VST), measured using infrared thermography (IRT), occur during estrus. Materials and methods: The experimental groups consisted of 25 gilts and 27 multiparous sows. Infrared VST and gluteal skin temperature (GST) were measured twice daily (8:00 am and 4:00 pm) using a thermal-imaging camera (Fluke IR FlexCam; Fluke Corporation, Everett, Washington). Once standing estrus was observed, transrectal real-time B-mode ultrasonography was performed twice daily (8:00 am and 4:00 pm) to monitor follicle development and determine time of ovulation. Mean VST and GST (± SEM) were reported and compared using MANOVA and Tukey-Kramer tests in SAS 9.1 (SAS Inc, Cary, North Carolina). Significant differences were reported at P <.05. Results: Evidence of ovulation was detected at approximately 38 ± 9 and 43 ± 12 hours after the onset of estrus in gilts and sows, respectively. Overall, daily VST and GST were significantly higher (P < .05) in sows than in gilts. During estrus, VST rose as estrus began and fell significantly (1.5°C; P < .05) 36 to 12 hours prior to ovulation in both sows and gilts. There was no significant difference between daily GST measurements (P > .05), but the difference between VST and GST was significant (P < .01) over time. Implications: This study demonstrated that VST of sows and gilts, measured by IRT, changes significantly during estrus. The potential to use digital infrared thermography as an adjunct tool during estrus detection in swine appears to be promising.en
dc.description.versionPublished versionen
dc.format.extent151 - 155 page(s)en
dc.format.mimetypeapplication/pdfen
dc.identifier.urihttp://hdl.handle.net/10919/73232en
dc.identifier.volume19en
dc.language.isoenen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.titleVulvar skin temperature changes significantly during estrus in swine as determined by Digital Infrared Thermographyen
dc.title.serialJournal of Swine Health and Productionen
dc.typeArticle - Refereeden
dc.type.dcmitypeTexten
pubs.organisational-group/Virginia Techen
pubs.organisational-group/Virginia Tech/All T&R Facultyen
pubs.organisational-group/Virginia Tech/Veterinary Medicineen
pubs.organisational-group/Virginia Tech/Veterinary Medicine/CVM T&R Facultyen
pubs.organisational-group/Virginia Tech/Veterinary Medicine/Large Animal Clinical Sciencesen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
v19n3p151-jshap 2011.pdf
Size:
329.19 KB
Format:
Adobe Portable Document Format
Description:
Publisher's Version
License bundle
Now showing 1 - 1 of 1
Name:
VTUL_Distribution_License_2016_05_09.pdf
Size:
18.09 KB
Format:
Adobe Portable Document Format
Description: