A Protocol to Determine the Performance of South Facing Double Glass Façade System-A Preliminary Study of Active/Passive Double Glass Façade Systems

TR Number

Date

2000-12-19

Journal Title

Journal ISSN

Volume Title

Publisher

Virginia Tech

Abstract

This project proposes a protocol for experimentally determining the performance of a double glass envelope system. As a proof of concept, the protocol was applied to an experimental study of a south-facing, single story double glazed ventilated wall system. Two modular full-scale double glazed window models with naturally or mechanically assisted ventilation were constructed and monitored for a range of weather conditions. The goals of this investigation were to develop and apply the test protocol and to monitor and analyze the thermal performance of these two systems and to improve our understanding of the double façade system. Using this test protocol preliminary results show the average cavity heat removal rate is approximately 25% higher for the active system when compared to the naturally ventilated system. Also, the passive system has a higher temperature difference between the indoor glass surface and the indoor air than the active system. This experimental protocol can be further applied to determine other performance issues of the double envelope system.

Description

Keywords

double glass façade, energy efficiency, double envelope, intelligent façade

Citation

Collections