Virginia Tech
    • Log in
    View Item 
    •   VTechWorks Home
    • ETDs: Virginia Tech Electronic Theses and Dissertations
    • Masters Theses
    • View Item
    •   VTechWorks Home
    • ETDs: Virginia Tech Electronic Theses and Dissertations
    • Masters Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Relamping hotel guestrooms to decrease operating costs

    Thumbnail
    View/Open
    LD5655.V855_1996.K545.pdf (30.14Mb)
    Downloads: 289
    Date
    1996-04-05
    Author
    Kieliszewski, Cheryl A.
    Metadata
    Show full item record
    Abstract

    The purpose of this study was to determine if the hotel industry could reduce a portion of its operating costs used for unnecessary lighting expenses. The study was conducted at the Donaldson Brown Center in Blacksburg, Virginia with 32 hotel guests participating. Data was collected to determine light fixture usage during periods of guestroom inactivity (inactive is defined as periods after the guest had checked-in but was out of the guestroom). Two treatment rooms and two control rooms were monitored to determine inactivity of the room, usage of light fixtures, and usage of daylight. Light levels and wattage readings were taken to determine consistency in light levels of the lamps and energy used by the different fixture/lamp combinations in each of the four rooms. One treatment room and one control room were on the east side of the building and the other treatment and control room were on the west side. The test rooms were evaluated to insure that all interior variables (i.e., structural configuration, size, materials and finishes, furnishings, light fixtures, and HV AC system) were controlled. The only features changed in the guest rooms were lamps housed in the fixtures of the two treatment rooms where the ceiling fixtures were relamped with two 16 watt compact fluorescent lamps (CFLs) and portable fixtures were relamped with one 18 watt CFL. Standard incandescent lamps were used in the control rooms. It was found that the time lights arc left on in inactive rooms can amount to a considerable portion of a hotels operating costs for energy usage. Results show a 64-71 % reduction in energy consumed by CFLs compared to incandescent lamps. Fixtures housed with incandescent lamps cost an average of $.008 per hour to run compared to those lamped with CFLs which cost $.003 per hour to run. Through total or strategic relamping of fixtures, operating costs for electric lighting can be cut by more than 50% and energy resources would be saved. Implemented environmental strategies could then be used as a marketing tool to attract environmentally conscious consumers.

    URI
    http://hdl.handle.net/10919/41026
    Collections
    • Masters Theses [19687]

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us
     

     

    VTechWorks

    AboutPoliciesHelp

    Browse

    All of VTechWorksCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Log inRegister

    Statistics

    View Usage Statistics

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us