    Feasibility Study in Development of a Wearable Device to Enable Emotion Regulation in Children with Autism Spectrum Disorder

    Thumbnail
    View/Open
    Hora_MK_T_2014.pdf (2.080Mb)
    Downloads: 949
    Supporting documents (516.9Kb)
    Downloads: 288
    Date
    2014-09-17
    Author
    Hora, Manpreet Kaur
    Metadata
    Show full item record
    Abstract
    Autism spectrum disorder (ASD) is a group of developmental disabilities characterized by impairments in social interaction and communication and by difficulties in emotion recognition and regulation. There is currently no cure for autism but psychosocial interventions and medical treatments exist. However, very few of them have been trialed on young children and others pose limitations. Strengthening young children's capacity to manage their emotions is important for academic success. Thus it becomes important to design and test the feasibility of an appropriate methodology that can teach emotion regulation to young children (age 3-6 years) with ASD. This thesis addresses the problem by proposing a novel framework that integrates physiology with Cognitive Behavior Theory to enable emotion regulation in the target population by exposing them to real-time stressful situations. The framework uses a feedback loop that measures the participant's physiology, estimates the level of stress being experienced and provides an audio feedback. The feasibility of the individual building blocks of the framework was tested by conducting pilot studies on nine typically developing children (age 3-6 years). The attention capturing capacity of different audio representations was tested, and a stress profile generating system was designed and developed to map the measured physiology of the participant on to a relative stress level. 33 out of 43 instances of audio representations proved to be successful in capturing the participants' attention and the stress profiles were found to be capable of distinguishing between stressed and relaxed state of the participants with an average accuracy of 83%.
    URI
    http://hdl.handle.net/10919/50518
    Collections
    • Masters Theses [21567]

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us
     

     

    VTechWorks

    AboutPoliciesHelp

    Browse

    All of VTechWorksCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Log inRegister

    Statistics

    View Usage Statistics

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us