    A Study of Measuring Intracranial Pressure Using a Non-Invasive Piezoelectric Sensor

    Thumbnail
    View/Open
    Tran_PX_T_2014.pdf (40.59Mb)
    Downloads: 2122
    Supporting documents (333.0Kb)
    Downloads: 74
    Date
    2014-10-10
    Author
    Tran, Prenn Xuan
    Metadata
    Show full item record
    Abstract
    The brain, like many parts of the human body, can experience swelling, also known as cerebral edema. Cerebral edema may occur because of an injury, health related issues, tumors, or even high altitudes[1]. When cerebral edema occurs, a rise in intracranial pressure (ICP) becomes prevalent and may cause a serious threat. Without immediate treatment, increased intracranial pressure can prevent blood from flowing to the brain and depriving it of necessary oxygen it needs to function. A normal ICP is usually between 5-15 mmHg (666 Pa - 1333Pa). Any ICP observed to be above 20 mmHg (2666Pa) can be associated with brain ischemia and is usually treated[2, 3]. If prolonged, high intracranial pressures can be fatal. Current methods of measuring increased ICP are invasive and may involve drilling into the skull. Extreme invasive measures are not always suitable for certain situations. This thesis presents a study of a non-invasive sensor using piezoelectric PVDF wire to measure the ICP. The PVDF wire sensor is wrapped around the outer portion of the human head to measure the integrated hoop strain. Using this hoop strain, the pressure is then calculated from a known coupling factor of strain to pressure outputted from finite element modeling simulations. The coupling factor is then incorporated into a final calibration factor to calibrate the piezoelectric PVDF wire sensor from charge (Picocoulomb) to pressure (Pascal). These calibration factors are proven to be primarily dependent on the circumference of the human skull. Furthermore, part of this study analyzed the effectiveness and validity of the sensor due to asymmetries in the human skull. A comparison of analytical analysis results versus computational results using finite element modeling simulations show that the PVDF wire sensor neglects any asymmetries presented within the test subject. The results of this study show that this sensor will output correct ICP measurements of different subjects using appropriate calibration factors and is a viable option for measuring ICP non-invasively.
    URI
    http://hdl.handle.net/10919/52573
    Collections
    • Masters Theses [21468]

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us
     

     

    VTechWorks

    AboutPoliciesHelp

    Browse

    All of VTechWorksCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Log inRegister

    Statistics

    View Usage Statistics

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us