Analytical and experimental investigation of a flush moment end-plate connection with six bolts at the tension flange

TR Number

Date

1989

Journal Title

Journal ISSN

Volume Title

Publisher

Virginia Polytechnic Institute and State University

Abstract

An analytical and experimental investigation was conducted to study the six bolt flush moment end-plate connection configuration which is used in steel frame construction. The limit states of plate yielding and bolt fracture were analyzed using yield-line theory to predict endplate thicknesses and a split-tee analogy to develop a method to predict bolt forces. Five experimental tests were conducted on four configurations within a matrix of geometric parameters. The predicted ultimate moment showed good . correlation to the yield moment obtained from the experimental deflection plots. The experimental bolt forces correlated well with the predicted bolt forces when plotted versus the applied moment. Additionally, an equation to model the moment-rotation relationship was developed from a regression analysis to determine the construction type suitable for a given connection configuration. Finally, a method of designing the six-bolt flush end-plate configuration is presented and an example given.

Description

Keywords

Citation

Collections