VTechWorks staff will be away for the winter holidays starting Tuesday, December 24, 2024, through Wednesday, January 1, 2025, and will not be replying to requests during this time. Thank you for your patience, and happy holidays!
 

Assessment of direct methods in power system transient stability analysis for on-line applications

dc.contributor.authorLlamas, Armandoen
dc.contributor.committeechairDe La Ree, Jaimeen
dc.contributor.committeememberPhadke, Arun G.en
dc.contributor.committeememberMili, Lamine M.en
dc.contributor.committeememberBaumann, William T.en
dc.contributor.committeememberJohnson, Lee W.en
dc.contributor.departmentElectrical Engineeringen
dc.date.accessioned2014-08-13T14:38:49Zen
dc.date.available2014-08-13T14:38:49Zen
dc.date.issued1992en
dc.description.abstractThe advent of synchronized phasor measurements allows the problem of real time prediction of instability and control to be considered. The use of direct methods for these on-line applications is assessed. The classical representation of a power system allows the use of two reference frames: Center of angle and one machine as reference. Formulae allowing transition between the two reference frames are derived. It is shown that the transient energy in both formulations is the same, and that line resistances do not dampen system oscillations. Examples illustrating the mathematical characterization of the region of attraction, exit point, closest u.e.p. and controlling u.e.p. methods are presented. Half-dimensional systems (reduced-order systems) are discussed. The general expression for the gradient system which accounts for transfer conductances is derived without making use of the infinite bus assumption. Examples illustrating the following items are presented: a) Effect of the linear ray approximation on the potential energy (inability to accurately locate the u.e.p.’s); b) Comparison of Kakimoto’s and Athay’s approach for PEBS crossing detection; c) BCU method and; d) One·parameter transversality condition. It is illustrated that if the assumption of the one-parameter transversality condition is not satisfied, the PEBS and BCU methods may give incorrect results for multi-swing stability. A procedure to determine if the u.e.p. found by the BCU method lies on the stability boundary of the original system is given. This procedure improves the BCU method for off~line applications when there is time for a hybrid approach (direct and conventional), but it does not improve it for on-line applications due to the following: a) It is time consuming and b) If it finds that the u.e.p. does not belong to the stability boundary it provides no information concerning the stability/instability of the system.en
dc.description.adminincomplete_metadataen
dc.description.degreePh. D.en
dc.format.extentx, 181 leavesen
dc.format.mimetypeapplication/pdfen
dc.identifier.urihttp://hdl.handle.net/10919/49933en
dc.publisherVirginia Polytechnic Institute and State Universityen
dc.relation.isformatofOCLC# 27864335en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V856 1992.L626en
dc.subject.lcshSynchrocyclotronsen
dc.subject.lcshReal-time controlen
dc.subject.lcshReal-time data processingen
dc.subject.lcshOnline data processingen
dc.titleAssessment of direct methods in power system transient stability analysis for on-line applicationsen
dc.typeDissertationen
dc.type.dcmitypeTexten
thesis.degree.disciplineElectrical Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.leveldoctoralen
thesis.degree.namePh. D.en

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LD5655.V856_1992.L626.pdf
Size:
4.96 MB
Format:
Adobe Portable Document Format
Description: