The effect of chromium plating on the endurance limit of 4340 steel
Files
TR Number
Date
1952-06-05
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Virginia Tech
Abstract
The percentage of reduction in fatigue limit of AISI 4340 steel due to one chromium plating was 21 percent, based on the fatigue limit of unplated AISI 4340 steel.